| FILE NO. | |
|
|
|
|
|
|
|
|
|
| ||
| Item |
|
| Operation flow and applicable data, etc. |
|
| Description | ||||
|
|
|
|
|
|
|
|
|
|
| |
11. |
|
|
|
| 1. | Purpose | |||||
function |
|
|
|
|
|
|
|
| The | ||
|
|
|
|
|
|
|
|
|
| growth of mold, bacteria etc. by running | |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| the fan and drying so as to keep the | |
|
| Unit now performing cooling or dry operation |
|
|
| inside of the air conditioner clean. | |||||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| When the cooling or dry operation shuts | |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| down, the unit automatically starts the Self- | |
|
|
|
| Press “STOP” button |
|
|
|
| |||
|
|
|
|
|
|
|
| Cleaning operation which is then performed | |||
|
|
|
|
|
|
|
|
|
| for the specified period based on duration | |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| of the operation which was performed | |
|
|
|
|
|
|
|
|
|
| prior to the shutdown, after which the | |
| Only timer indicator lights, and Self Cleaning operation starts |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| (The | |
|
|
|
|
|
|
|
|
|
| performed after a heating operation.) | |
|
|
|
|
|
|
|
|
| 2. | Operation | |
|
|
|
|
|
|
|
|
| |||
|
|
|
| Time set now elapses |
|
|
| ||||
|
|
|
|
|
|
|
| 1) When the stop signal from the remote | |||
|
|
|
|
|
|
|
|
|
| controller or | |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| only the timer indicator light. | |
|
|
|
|
|
|
|
|
|
| 2) The period of the | |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| Operation stops |
|
|
|
| is determined by the duration of the | ||
|
|
|
|
|
|
|
|
|
| operation performed prior to the | |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| reception of the stop code. | |
|
|
|
|
|
|
|
|
|
| 3) After the | |
|
|
|
|
|
|
|
|
|
| been performed for the specified period, | |
|
|
|
|
|
|
|
|
|
| the unit stops operating. | |
|
|
| • During |
|
|
|
| ||||
|
|
|
| slightly. The indoor fan operates continuously at |
|
|
|
| |||
|
|
|
| a speed of 500 rpm. |
|
|
|
|
|
| |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| Operation time |
| ||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Up to 10 minutes | No |
| |||
|
|
|
|
|
| performed (0 minutes) |
| ||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| Cooling: Auto (cooling) Dry | 10 minutes | 30 mins. |
| ||||
|
|
|
|
|
| or longer |
| ||||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Heating: Auto (heating) |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |||
|
|
|
| Auto (fan only) | No |
| |||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Shutdown |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
•To stop an ongoing
Press the start/stop button on the remote controller twice during the
second time without delay (within 10 minutes).)