FILE NO. SVM-07008

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

Operation flow and applicable data, etc.

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

11. Self-Cleaning

 

 

 

 

1.

Purpose

function

 

 

 

 

 

 

 

 

The Self-Cleaning operation is to minimize the

 

 

 

 

 

 

 

 

 

 

growth of mold, bacteria etc. by running

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the fan and drying so as to keep the

 

 

Unit now performing cooling or dry operation

 

 

 

inside of the air conditioner clean.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Self-Cleaning operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When the cooling or dry operation shuts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

down, the unit automatically starts the Self-

 

 

 

 

Press “STOP” button

 

 

 

 

 

 

 

 

 

 

 

 

Cleaning operation which is then performed

 

 

 

 

 

 

 

 

 

 

for the specified period based on duration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of the operation which was performed

 

 

 

 

 

 

 

 

 

 

prior to the shutdown, after which the

 

Only timer indicator lights, and Self Cleaning operation starts

 

 

 

Self-Cleaning operation stops.

 

 

 

 

 

 

 

 

 

 

(The Self-Cleaning operation is not

 

 

 

 

 

 

 

 

 

 

performed after a heating operation.)

 

 

 

 

 

 

 

 

 

2.

Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

Time set now elapses

 

 

 

 

 

 

 

 

 

 

 

1) When the stop signal from the remote

 

 

 

 

 

 

 

 

 

 

controller or timer-off function is received,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

only the timer indicator light.

 

 

 

 

 

 

 

 

 

 

2) The period of the Self-Cleaning operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation stops

 

 

 

 

is determined by the duration of the

 

 

 

 

 

 

 

 

 

 

operation performed prior to the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reception of the stop code.

 

 

 

 

 

 

 

 

 

 

3) After the Self-Cleaning operation has

 

 

 

 

 

 

 

 

 

 

been performed for the specified period,

 

 

 

 

 

 

 

 

 

 

the unit stops operating.

 

 

 

• During Self-Cleaning operations: The louver opens

 

 

 

 

 

 

 

 

slightly. The indoor fan operates continuously at

 

 

 

 

 

 

 

 

a speed of 500 rpm.

 

 

 

 

 

 

 

 

 

Self-Cleaning operation times

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation time

Self-Cleaning operation time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Up to 10 minutes

No Self-Cleaning operation

 

 

 

 

 

 

 

performed (0 minutes)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling: Auto (cooling) Dry

10 minutes

30 mins.

 

 

 

 

 

 

 

or longer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating: Auto (heating)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto (fan only)

No Self-Cleaning operation performed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shutdown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To stop an ongoing Self-Cleaning operation at any time

Press the start/stop button on the remote controller twice during the Self-Cleaning operation. (After pressing the button for the first time, press it for the

second time without delay (within 10 minutes).)

36