FILE NO.
Wiring of the connecting cable can be carried out without removing of the front panel.
1. Remove the air inlet grille. |
*Since dewing results in a machine trouble, make sure to insulate both the connecting pipes. (Use polyethylene foam as insulating material.)
| Open the air inlet grille upward and pull it toward |
| you. |
2. | Remove the terminal cover and cord clamp. |
3. | Insert the connecting cable (according to the local |
| cords) into the pipe hole on the wall. |
4. | Take out the connecting cable through the cable |
| slot on the rear panel so that it protrudes about |
| 15 cm from the front. |
5. | Insert the connecting cable fully into the terminal |
| block and secure it tightly with screws. |
6. | Tightening torque : 1.2 N·m (0.12 kgf·m) |
7. | Secure the connecting cable with the cord clamp. |
Rear right
Rear left
Bottom left
Left
Bottom right
Right
|
|
|
| Pipingpreparation | |
|
| Changing drainhose |
| ||
|
|
| |||
|
|
|
|
|
8. Fix the terminal cover, rear plate bushing and air |
inlet grille on the indoor unit. |
CAUTION
•Be sure to refer to the wiring system diagram labeled inside the front panel.
•Check local electrical cords and also any specific wiring instructions or limitations.
Fig.
Cut out the slit on the left or right side of the front panel for the left or right connection and the slit on the bottom left or right side of the front panel for the bottom left or right connection with a pair of nippers.
2. Changing drain hoseFor left connection,
Cord clamp
Terminal cover
Screw
Terminal block
change the drain hose and drain cap.
<How to remove the Drains Cap>1 | 2 | 3 | 1 | 2 | 3 |
|
|
| |||
|
|
|
|
Earth line
Clip drain cap by
Screw | Connecting cable |
Screw
110 mm
10 mm
Connecting cable
about |
|
|
15 | cm | 10 mm |
Earth line
Fig.
Firmly insert drain hose connecting part until hitting on
50 mm
Stripping length of the connecting cable
a heat insulator.
NOTE :
•Use stranded wire only.
•Wire type :
•When attaching the air inlet grille, the contrary of the removed operation is performed.
Heat insulator