FILE NO. SVM-07008

10-2-4. Wiring connection<How to connect the connecting cable>

Wiring of the connecting cable can be carried out without removing of the front panel.

1. Remove the air inlet grille.

10-2-5. Piping and drain hose installation<Piping and Drain Hose Forming>

*Since dewing results in a machine trouble, make sure to insulate both the connecting pipes. (Use polyethylene foam as insulating material.)

 

Open the air inlet grille upward and pull it toward

 

you.

2.

Remove the terminal cover and cord clamp.

3.

Insert the connecting cable (according to the local

 

cords) into the pipe hole on the wall.

4.

Take out the connecting cable through the cable

 

slot on the rear panel so that it protrudes about

 

15 cm from the front.

5.

Insert the connecting cable fully into the terminal

 

block and secure it tightly with screws.

6.

Tightening torque : 1.2 N·m (0.12 kgf·m)

7.

Secure the connecting cable with the cord clamp.

Rear right

Rear left

Bottom left

Left

Bottom right

Right

 

 

 

 

Pipingpreparation

 

 

Changing drainhose

 

Die-cutting Frontpanelslit

 

 

 

 

 

 

 

 

8. Fix the terminal cover, rear plate bushing and air

inlet grille on the indoor unit.

CAUTION

Be sure to refer to the wiring system diagram labeled inside the front panel.

Check local electrical cords and also any specific wiring instructions or limitations.

Fig. 10-2-8

1. Die-cutting Front panel slit

Cut out the slit on the left or right side of the front panel for the left or right connection and the slit on the bottom left or right side of the front panel for the bottom left or right connection with a pair of nippers.

2. Changing drain hose

For left connection, bottom-leftward connection and rear-leftward connection’s piping, it is necessary to

Cord clamp

Terminal cover

Screw

Terminal block

change the drain hose and drain cap.

<How to remove the Drains Cap>

1

2

3

1

2

3

 

 

 

 

 

 

 

Earth line

Clip drain cap by needle-nose pliers, and pull out.

Screw

Connecting cable

Screw

110 mm

10 mm

Connecting cable

about

 

 

15

cm

10 mm

Earth line

Fig. 10-2-9

<How to install the Drain Hose>

Firmly insert drain hose connecting part until hitting on

50 mm

Stripping length of the connecting cable

a heat insulator.

NOTE :

Use stranded wire only.

Wire type : H07RN-F or more

<How to install the air inlet. grille on the indoor unit>

When attaching the air inlet grille, the contrary of the removed operation is performed.

Heat insulator

Drain hose

Fig. 10-2-10

– 53 –