<When the installation plate is directly mounted on the wall>

1.Securely fit the installation plate onto the wall by screwing it in the upper and lower parts to hook up the indoor unit.

2.To mount the installation plate on a concrete wall with anchor bolts, utilize the anchor bolt holes as illustrated in the above figure.

3.Install the installation plate horizontally in the wall.

CAUTION

When installing the installation plate with a mounting screw, do not use the anchor bolt hole. Otherwise the unit may fall down and result in personal injury and property damage.

Installation plate

<Keep horizontal direction>

Anchor bolt

Projection 15 mm or less

FILE NO. SVM-07008

10-2-3. Electrical work

1.The supply voltage must be the same as the rated voltage of the air conditioner.

2.Prepare the power source for exclusive use with the air conditioner.

CAUTION

This appliance can be connected to the mains in either of the following two ways.

(1)Connection to fixed wiring:

A switch or circuit breaker which disconnects all poles and has a contact separation of at least 3 mm must be incorporate in the fixed wiring. An approved circuit breaker or switches must used.

(2)Connection with power supply plug: Attach power supply plug with power cord and plug it into wall outlet. An approved power supply cord and plug must be used.

NOTE

Ensure all wiring is used within its electrical rating.

Fig. 10-2-4

5 mm dia. hole

7 Mounting screw

4 x 25s

Clip anchor (local parts)

Fig. 10-2-5

CAUTION

Failure to firmly install the unit may result in personal injury and property damage if the unit falls.

In case of block, brick, concrete or similar type walls, make 5 mm dia. holes in the wall.

Insert clip anchors for appropriate mounting screws

7.

NOTE:

Secure four corners and lower parts of the installation plate with 4 to 6 mounting screws to install it.

Model

10 Class

 

 

Power source

50Hz, 220 - 240 V Single phase

 

 

Maximum

7.5A

running current

 

 

 

Plug socket &

16A

fuse rating

 

 

 

Power cord

1 mm2 or more

 

 

– 52 –