FILE NO. SVM-07008

No.

Part name

Procedures

Remarks

3

Inverter

1) Perform work of item 1 of 1.

Inverter cover

 

assembly

2) Remove screw (ST1T4 x 10s 1 pc.) of

PC board

 

 

the upper part of the front cabinet.

 

 

If removing the inverter cover in this

(Soldered surface)

 

 

 

 

 

condition, the P.C. board can be checked.

 

 

 

If there is no space in the upper part of

 

 

 

the upper cabinet, perform work of 2.

 

 

 

Be careful when checking the

 

 

 

inverter because high-voltage

 

 

 

circuit is incorporated in it.

 

 

 

3) Perform discharging by connecting the

Discharging time

 

 

e,d polarities by discharging resistance

(Discharging period

 

 

10 seconds or more)

 

 

(approx. 10040W) or plug of soldering

 

 

Plug of

 

 

iron to e,d terminals of the C13 (printed

soldering iron

 

 

“CAUTION HIGH VOLTAGE” is attached.)

 

 

 

electrolytic capacitor (760 F/400 WV) on

 

 

 

the P.C. board.

 

Be careful to discharge the capacitor because the electrolytic capacitor cannot naturally discharge and voltage remains depending on the malfunction state in some cases.

 

NOTE :

 

 

This capacitor has mass capacity.

 

 

Therefore, it is dangerous that a

 

 

large spark generates if short-

 

 

circuiting between the e,d polarities

 

 

with screwdriver, etc. for discharging.

 

4)

Perform the work of 2.

 

5) Remove the screw (ST1T4 x 10s 1 pc.)

 

 

fixing the main body and the inverter box.

 

6) Remove the lead wire from the holder on

 

 

the terminal block.

 

7)

Disconnect the connectors of various lead

Terminal

 

wires.

block

 

 

Partition

 

Requirement :

 

 

As each connector has a lock

The connector is one with lock,

 

mechanism, avoid removing the

 

so remove it while pushing the

 

connector by holding the lead wire,

 

part indicated by an arrow.

 

but by holding the connector.

 

 

Be sure to remove the connector by holding the connector, not by pulling the lead wire.

– 84 –