FILE NO. SVM-07008

7-2. Operation Data <Cooling>
TempeatureModel nameStandardHeat exchanger

Indoor

Outdoor

Compressor

condition(°C)RAS-pressure

pipe temp.

fan mode

fan mode

revolution

Indoor

Outdoor

 

P (MPa)T1 (°C)T2 (°C)

 

 

(rps)

27/19

35/-

10SKV-E

0.9 to 1.1

9 to 11

47 to 49

High

High

54

 

 

10SKV-A

 

 

 

 

 

 

 

 

<Heating>

Tempeature

Model name

Standard

Heat exchanger

Indoor

Outdoor

Compressor

condition(°C)

RAS-

pressure

pipe temp.

fan mode

fan mode

revolution

Indoor

Outdoor

 

P (MPa)

T1 (°C)

T2 (°C)

 

 

(rps)

20/-

7/6

10SKV-E

2.4 to 2.6

43 to 45

0 to 3

High

High

68

 

 

10SKV-A

 

 

 

 

 

 

 

 

NOTES :

1.Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent. (Thermistor themometer)

2.Connecting piping condition : 5 m

– 21 –