FILE NO.
Tempeature | Model name | Standard | Heat exchanger | Indoor | Outdoor | Compressor | ||
condition(°C) | RAS- | pressure | pipe temp. | fan mode | fan mode | revolution | ||
Indoor | Outdoor |
| P (MPa) | T1 (°C) | T2 (°C) |
|
| (rps) |
27/19 | 35/- | 0.9 to 1.1 | 9 to 11 | 47 to 49 | High | High | 54 | |
|
| |||||||
|
|
|
|
|
|
|
|
Tempeature | Model name | Standard | Heat exchanger | Indoor | Outdoor | Compressor | ||
condition(°C) | RAS- | pressure | pipe temp. | fan mode | fan mode | revolution | ||
Indoor | Outdoor |
| P (MPa) | T1 (°C) | T2 (°C) |
|
| (rps) |
20/- | 7/6 | 2.4 to 2.6 | 43 to 45 | 0 to 3 | High | High | 68 | |
|
| |||||||
|
|
|
|
|
|
|
|
1.Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent. (Thermistor themometer)
2.Connecting piping condition : 5 m
– 21 –