FILE NO. SVM-07008

6-2. Outdoor Unit (RAS-10SAV-E, RAS-10SAV-A)

 

 

 

 

 

 

 

 

No.

Parts name

 

Model name

Rating

 

 

 

 

 

 

 

1

SC coil

 

L01

GET-0451

0.6mH, 15A

 

 

 

 

 

 

 

 

(Noise filter)

 

L03

GET-0452

2.0 mH, 10A

 

 

 

 

 

 

 

2

DC-DC transformer

 

SWT-72

Primary side DC280V, Secondary

 

 

 

 

 

side 7.0 V x 1, 12 V x 1, 17V x 2

3

Reactor

 

CH-51-Z-T

L=19mH, 10A

 

 

 

 

 

4

Outside fan motor

 

SKF-240-20B-1

20W

5

Fan control relay

 

G5NB-1A

Coil DC12V Contact AC250V-1.5A

 

 

 

 

 

 

 

6

Outside air temp.

 

(Inverter attached)

10kΩ (25°C)

sensor (TO sensor)

 

 

 

 

 

 

7

Heat exchanger temp.

(Inverter attached)

10kΩ (25°C)

sensor (TE sensor)

 

 

 

 

 

 

 

 

 

 

 

 

8

Dischenge temp.

 

(Inverter attached)

62kΩ (20°C)

sensor (TD sensor)

 

 

 

 

 

 

 

 

 

 

 

 

9

Terminal block (6P)

 

JX0-6B

20A, AC250V

 

 

 

 

 

 

 

10

Fuse

 

For protection of switching power source

3.15A, AC250V

 

 

 

 

 

For protection of inverter input overcurrent

25A, AC250V

 

 

 

 

 

 

 

 

 

 

11

Electrolytic capacitor

 

LLQ2G501KHUBTF

500μF, DC 400 V x 3 pieces

 

 

 

 

 

 

12

IGBT

 

GT15J321

15A, 600

 

 

 

 

 

 

13

Compressor

 

DA89X1C-23FZ

3-phases 4-poles 750W

14

Compressor thermo.

 

PW-2AL

OFF: 125 ± 4°C, ON: 90 ± 5°C

15

Rectifier

 

D15XB60-4001

15A, 600V

 

 

 

 

 

 

16

4-way valve coil

 

AC220-240V

 

 

 

 

 

 

17

Running capacitor

 

DS451155NPQB

AC 450V~, 1.5μF

 

(for fan motor)

 

 

 

 

 

 

 

 

 

 

 

– 19 –