FILE NO. SVM-07008

 

 

 

 

Item

 

Operation flow and applicable data, etc.

Description

 

 

 

13. Romote-A or B

Setting the remote controller

1. Purpose

selection

To separate using of remote control for each indoor

This operation is to operate only one

 

 

unit in case of 2 air conditioner are installed nearly.

indoor unit using one remote controller.

 

Remote Control B Setup.

2. Description

 

1)

Press RESET button on the indoor unit to turn

 

When operating one indoor unit in a

 

 

the air conditioner ON.

 

 

situation where two indoor units have

 

2)

Point the remote control at the indoor unit.

 

been installed in the same room or

 

 

Push and hold CHK button on the Remote

 

3)

nearby rooms, this operation prevents the

 

 

Control by thetip of the pencil. "00" will be shown

remote controller signal from being

 

 

shown on the display.

received simultaneously by both units,

 

4)

Press MODE during pushing CHK . "B" will

thus preventing both units from operating.

 

 

 

 

show on the display and "00" will disappear and

3. Operation

 

 

the air conditioner will turn OFF. The Remote

The indoor unit on which the remote

 

 

Control B is memorized.

controller selection has been set to B

 

 

 

receives the signal of the remote control-

 

Note : 1. Repeat above step to reset Remote Control

ler also set to B.

 

 

to be A.

(At the factory the remote controller

 

 

2. Remote Control A has mot "A" display.

selection is set to A on all the indoor

 

 

units. There is no A setting display.)

 

 

3. Default setting of Remote Control from

 

 

 

 

 

factory is A.

 

 

 

 

 

38