FILE NO. SVM-07008

Item

Operation flow and applicable data, etc.

Description

11.Self-CleaningSelf-Cleaning diagram function

Operation display

 

ON

 

OFF

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

FCU fan

 

ON

 

ON

 

OFF

rpm is depend on presetting.

 

(500RPM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FCU louver

 

OPEN

 

OPEN (12.7º)

 

CLOSE

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer display

 

ON or OFF

 

ON

 

ON or OFF

depend on presetting of timer function.

 

 

depend on presetting of timer function.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor

 

ON or OFF

 

OFF

 

OFF

depend on presetting per room temperature.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CDU fan

 

ON or OFF

 

OFF

 

OFF

 

depend on presetting per room temperature.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cool mode or dry mode

 

Self-Cleaning mode

 

Operation time

 

 

 

 

 

 

 

 

 

 

 

 

operation more than 10 mins.

 

 

 

 

operate 30 mins.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn off by remote controller or

Automatically turn-off.

 

timer-off function.

 

12.Self-Cleaning function release

How to cencel Self-Cleaning function

To cancel the Self-Cleaning function, proceed as follows:

Press [RESET] button one time or use remote control to turn on air conditioner. Display will show in green color.

Hold down the [RESET] button for more than

20 seconds. (The air conditioner will stop suddenly when the [RESET] is pressed but keep holding it continue. The will beep 3 times in the first

3 seconds but it is not related to Self-Cleaning function)

After holding about 20 seconds, the air conditioner will beep 5 times without any blinking of display.

The Self-Cleaning Operation had been cancelled.

Remark

Presetting of Self-Cleaning function above, AUTO- RESTART function had been cancelled. To set AUTO-RESTART again, please follow item 9-3-1

How to set Self-Cleaning function

To set the Self-Cleaning function, proceed as follows.

Press [RESET] button one time or use remote

control to turn on air conditioner. Display will show in green color.

Hold down the [RESET] button for more than

20 seconds. (The air conditioner will stop suddenly when the [RESET] is pressed but keep holding it continue. Then will beep 3 times is the first 3 seconds but it is not related to Self-Cleaning function)

After holding about 20 seconds, the air conditioner will beep 5 times and OPERATION display blinks 5 times.

The Self-Cleaning function had been set. Remark

Presetting of Self-Cleaning function above, AUTO- RESTART function had been cancelled. To set AUTO-RESTART again, please follow item 9-3-1

RESET button