FILE NO.
9. OPERATION DESCRIPTION
9-1. Outline of Air Conditioner Control
This air conditioner is a
fan motor and the outdoor fan motor. And the capacity- proportional control compressor which can change the motor speed in the range from 22 to 83 rps is mounted. The AC motor drive circuit is mounted to the indoor unit. The compressor and the inverter is mounted to the outdoor unit.
The entire air conditioner is mainly controlled by the indoor unit controller.
The indoor unit controller drives the indoor fan motor based upon command sent from the remote controller, and transfers the operation command to the outdoor unit controller.
The outdoor unit controller receives operation command from the indoor unit side, and controls the
outdoor fan motor. Besides detecting revolution position
of the compressor motor, the outdoor unit controller controls speed of the compressor motor by controlling
output voltage of the inverter and switching timing of the supply power (current transfer timing) so that motors
drive according to the operation command.
And then, the outdoor unit controller transfers reversely the operating status information of the outdoor unit to control the indoor unit controller.
As the compressor adopts four
The indoor unit controller judges the operation commands from the remote controller and assumes the following functions.
∙Judgment of suction air temperature of the indoor heat exchanger by using the indoor temp. sensor. (TA sensor)
∙Judgment of the indoor heat exchanger tempera- ture by using heat exchanger sensor (TC sensor)
∙Louver motor control
∙Indoor fan motor operation control
∙LED (Light Emitting Diode) display control
∙Transferring of operation command signal (Serial signal) to the outdoor unit
∙Reception of information of operation status (Serial signal including outside temp. data) to the outdoor unit and judgment/display of error
2.Role of outdoor unit controllerReceiving the operation command signal (Serial signal) from the indoor unit controller, the outdoor
unit performs its role. | |
|
∙Detection of inverter input current and current release operation
∙
∙Compressor and outdoor fan stop function when serial signal is off (when the serial signal does not reach the board assembly of outdoor control by trouble of the signal system)
∙Transferring of operation information (Serial signal) from outdoor unit controller to indoor unit controller
∙Detection of outdoor temperature and operation revolution control
∙Defrost control in heating operation (Temp. measurement by outdoor heat exchanger and control for
3.Contents of operation command signal (Serial signal) from indoor unit controller to outdoor unit controller
The following three types of signals are sent from the indoor unit controller.
∙Operation mode set on the remote controller
∙Compressor revolution command signal defined by indoor temperature and set temperature (Correction along with variation of room tempera- ture and correction of indoor heat exchanger temperature are added.)
∙Temperature of indoor heat exchanger
∙For these signals ([Operation mode] and [Com- pressor revolution] indoor heat exchanger tem- perature), the outdoor unit controller monitors the input current to the inverter, and performs the followed operation within the range that current does not exceed the allowable value.
4.Contents of operation command signal (Serial signal) from outdoor unit controller to indoor unit controller
The following signals are sent from the outdoor unit controller.
∙The current operation mode
∙The current compressor revolution
∙Outdoor temperature
∙Existence of protective circuit operation
For transferring of these signals, the indoor unit controller monitors the contents of signals, and judges existence of trouble occurrence.
Contents of judgment are described below.
∙Whether distinction of the current operation status meets to the operation command signal
∙Whether protective circuit operates
When no signal is received from the outdoor unit controller, it is assumed as a trouble.
∙ | Compressor operation control | . |
|
| Operations followed to judgment |
∙ | of serial signal from indoor side |
− 24 −