| FILE NO. |
No. | Part name |
| Procedures | Remarks |
ƒ Fan motor | 1) | Perform work of item 1 of 1 and 1 of 2. |
| |
|
| 2) | Remove the flange nut fixing the fan motor | Fan motor |
|
|
| and the propeller fan. | Propeller fan |
|
|
| • Flange nut is loosened by turning |
|
|
|
| clockwise. |
|
|
|
| (To tighten the flange nut, turn counter- | Closed end |
|
|
| clockwise.) | |
|
|
| splice | |
|
| 3) | Remove the propeller fan. | |
|
|
| ||
|
| 4) | Disconnect the connector for the fan motor | Flange nut |
|
|
| from the inverter. | |
|
|
|
|
5)Remove the fixing screws (4 pcs.) holding the fan motor by hand so that it does not fall.
6)Cut the motor lead at the point which is 100 mm apart from the connector toward the fan.
7)Use the connector used for the inverter, and pinch the lead wires using the closed end splice.
„ Compressor | 1) | Perform work of item 1 of 1, 1 of 2 |
|
|
| and ƒ. |
|
| 2) | Extract refrigerant gas. |
|
| 3) | Remove the partition board. |
|
|
| (ST1T∅ 4 x 10s 3 pcs.) |
|
| 4) | Remove the |
|
| 5) | Remove the terminal cover of the |
|
|
| compressor, and disconnect the lead wire | Compressor |
|
| of the compressor thermo and the | |
|
|
| |
|
| compressor from the terminal. |
|
| 6) | Remove the pipe connected to the |
|
|
| compressor with a burner. |
|
|
| • Make sure the flame does not touch the |
|
|
| 4 way valve. |
|
| 7) | Remove the fixing screw of the base plate |
|
|
| and heat exchanger. |
|
|
| (ST1T∅ 4 x 10s 2 pcs.) |
|
| 8) | Pull upward the refrigeration cycle. |
|
| 9) | Remove the nut fixing the compressor to |
|
|
| the base plate. |
|
… Reactor | 1) | Perform work of item 1 of 1, 1 of 2, | Reactor |
|
| and 3. |
|
| 2) | Remove the screw fixing the reactor. |
|
|
| (ST1T∅ 4 x 10s 2 PCS.) |
|
– 86 –