FILE NO. SVM-07008

No. Part name

Procedures

Remarks

4Heat exchanger 1) Remove the front panel, electrical part and the horizontal louver following procedure 3.

2)Remove the pipe holder at the rear side of main unit.

3) Remove the 2 screws on the heat exchanger at the base bearing.

4) Remove the screw on the heat exchanger2 Pipe holder at the fixed plate from the back body and then

pull out the right hand side until the socket of heat exchanger released from the hook of the

band motor (L), and then pull out the upper side of heat exchanger slowly.

3

2-Screws

4 Screws

5

Cross flow fan 1) Remove the front panel, electrical part,

 

 

2-Screws (R)

 

horizontal louver and the heat exchanger

 

 

 

2

 

following procedure 4.

 

 

 

 

 

2) Remove the 2 screws on the band motor (L)

 

 

 

 

and remove the 2 screws on the band motor

 

 

 

 

(R) and then remove the cross flow fan.

 

 

 

 

3) Loosen the set screw of the cross flow fan

2 2-Screws (L)

 

then separate the fan and the fan motor.

 

 

4.7 mm

 

 

 

 

Notice

 

 

 

 

To assemble cross flow fan and fan motor to the

 

 

 

 

unit, please turn the fan motor unit the center of

 

 

 

 

its terminal meets the top position of band motor

 

 

 

 

 

 

 

 

(R).

 

 

 

 

Fix the cross flow fan with the set screw at the

 

 

 

 

6 Set screw

 

position where the gap between the back body

 

Middle of the fan motor terminal

 

and the right surface of the cross flow fan is

 

4.7 mm.

 

 

 

6

Base bearing

1)

Remove the front panel, electrical part,

 

 

 

 

horizontal louver, heat exchanger and the

 

 

 

 

cross flow fan following procedure 5.

 

 

 

2)

Remove the 2 screws fixing the base bearing.

 

 

 

3)

Remove the bearing from the base bearing. If

 

 

 

 

the housing protrudes from the base bearing,

2

 

 

 

put the housing in position and attach the

 

 

 

2-Screws

 

 

 

bearing to the base bearing.

 

 

 

 

80