Toshiba RAV-SM2802DT-E, RAV-SM2242DT-TR, RAV-SM2802DT-TR service manual P19 error, 45

Models: RAV-SM2802DT-TR RAV-SM2242DT-TR RAV-SM2802DT-E

1 110
Download 110 pages 30.72 Kb
Page 45
Image 45
[P19 error]

[P19 error]

NO

Is operation of 4-way valve normal?

YES

In heating mode,

4-way valve coil terminal 200V

YES

Check 4-way valve.

Defective Replace

NO

Is refrigerant flow by PMV normal?

YES

Check and replace PMV.

NO

Is circuit wiring normal?

YES

NO

Check and correct circuit.

Are resistance value characteristics

 

NO

Check CDB P.C. board.

NO

 

 

 

 

 

 

 

 

 

 

of TC sensor normal?

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check CDB P.C. board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace TC sensor.

 

 

 

Defective Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to temperature-Resistance value characteristic table.

Check indoor P.C. board (MCC-1403).

Defective Replace

In cooling operation, the outdoor unit [P19 error] may be displayed when high pressure is abnormally up.

In this case, referring to item [P04 error], eliminate the pressure-up cause and then diagnose the error again.

– 45 –

Page 45
Image 45
Toshiba RAV-SM2802DT-E, RAV-SM2242DT-TR, RAV-SM2802DT-TR service manual P19 error, 45