4 CORRECT USAGE

Concealed Duct High Static Pressure

Owner’s Manual

4 CORRECT USAGE

When you use the air conditioner for the first time or when you change the setting, follow the steps below. Settings are

saved in memory and are displayed anytime the unit is turned on by pushing the nPreparation button.

nPreparation

Turn on the main power switch and/or the leakage breaker.

When the power supply is turned on, a partition line is displayed on the display part of the remote controller.

After the power supply is turned on, the remote controller does not accept an operation for approx. 1 minute, but it is not a failure.

REQUIREMENT

While using the air conditioner, operate it only with REQUIREMENTStartStop button without turning off the main power switch and the leakage breaker.

When you re-power the air conditioner after it has not been used for a long period, turn on the leakage breaker at least 12 hours before starting the air conditioner. (This is required to turn on the compressor case heater for warming in order to prevent overload on the compressor when activating the outdoor unit.)

Concealed Duct High Static Pressure

Owner’s Manual

n8°C OPERATION (For object pre-heating) (Available for Super Digital Inverter outdoor units)

The air conditioner can control the heating temperature to about 8°C in the heating mode.

The 8°C heating operation requires settings with the wired remote controller. Ask the installer or dealer for the settings according to the installation manual of the indoor unit.

Start

1Set the displayed temperature to 18°C in the heating mode by pushing TEMP. – 76 – button.

2Set the displayed temperature to 8°C by pushing TEMP. Push  button. button for at least four seconds.

Stop

1Set the displayed temperature to 18°C by pushing TEMP. Auto Changeover button.

• The air conditioner returns to the normal HEAT mode. Select a desired temperature and operation mode.

NOTE

– 76 –

1 PushON / OFF

3

DE

NT

FILTER

RESET

button. 1

2 Select an operation mode with the2

Stop

Push 3 Select a desired set point by pushing button.

The operation lamp goes off, and the operation stops.

NOTE

Auto Changeover

When in Auto Mode, the unit selects the operating mode (cooling, heating or fan only) based on the user selected set point temperature.

If the Auto mode is uncomfortable, you can select the desired conditions manually.

The discharged air temperature is lower than that in the normal heating operation.

The room temperature may not be heated evenly depending on the remote controller installation location.

The room temperature may not reach 8°C depending on the room size or the installation conditions. The 8°C heating operation is cancelled in the following cases.

When operation is stopped withthe “TEMP.  ” or “TEMP.  ” button.button

When another operation mode is selected withCoolingbutton

When temperature setting or operation mode is changed or operation is started/stopped by the wireless remote controller or the central control remote controller.

If one or more models other than the 4-way air discharge cassette type (4 series), slim duct, Concealed Duct High Static Pressure are connected in the same control group, the 8°C heating operation is not available.

When you use this operation mode, observe proper operating hours and we recommend that you ask service staff for periodic maintenance of the air conditioner.

Start

1 Pushbutton.

The operation lamp illuminates, and the operation starts.

2 Select an operation mode with the

Heating ” button.

One push of the button, and the display changes in the order shown below.

Auto

Heat

 

 

Cool

 

 

Fan

 

 

 

 

 

 

 

 

 

 

3 Select a desired set point by pushingthe “TEMP. When restarting the operation after stop ” or “TEMP. Manual background ” button.
Cooling

If there is a demand for cooling, unit will start approximately 1 minute after mode is selected.

Heating

If there is a demand for heating, unit will start approximately 3 to 5 minutes after the mode is selected.

After the heating operation has stopped, fan may continue to run for approx. 30 seconds.

When the room temperature reaches the set temperature, the outdoor unit stops and the indoor unit will carry on fan operation.

During defrost operation, the fan stops so that cool air is not discharged. (“Manual backgroundPre-heat is displayed.)

When restarting the operation after stop

When attempting to restart the unit immediately after it was stopped, the unit can not start for approx. 3 minutes this is to protect the compressor.

– 11 –

– 12 –