Destination | • Remote COM1 using Slot1 Video Endpoint. This means that all |
| serial data originating at the COM1 port being configured is sent |
| to the COM1 port of the VBrick identified as the Slot1 video |
| source (if Slot1 is a decoder) or to the Slot1 video destination |
| VBrick (if Slot1 is an encoder). |
| • Remote COM2 using Slot1 Video Endpoint. Slot1 Destination 1 |
| only. Same as above except Initiator destination is COM2. |
| • Dedicated. When Passthrough State is set as Initiator and the |
| Destination is Dedicated, the VBrick appliance (whose serial port |
| is the destination of this COM port) can be configured and |
| identified using either an IP address or a host name. |
| • Slot1 MetaData. If Meta Data is enabled on the Encoder > Video |
| page, the appliance captures incoming data from the serial port |
| and inserts it into the stream as metadata. In a typical application, |
| a GPS receiver connected to a VBrick can insert ASCII strings |
| representing map coordinates into a stream. This information is |
| saved and sent as metadata with the video. For this feature to |
| function properly, captions must be enabled in the player (Play > |
| Captions and Subtitles). This feature is disabled when the |
| appliance is in Edit mode. |
| The data is inserted when it reaches the maximum number of |
| characters (58 for |
| between characters is reached. Note that a |
| command and a trailing space are |
| metadata. The Media Player recognizes the TEXT command and |
| displays the metadata. This feature works for all passthrough port |
| baud rates but can only accept continuous serial data at rates up to |
| 9600 baud; at higher rates there must be some idle time between |
| metadata strings. |
| • Slot2 MetaData. Same as above except the serial port data is |
| inserted as metadata in the video stream from the Slot2 encoder. |
|
|
Baud Rate | Rate of Passthrough port. Rate can be set to the following (Default = |
| 9600): 110, 300, 600, 1200, 2400, 3600, 4800, 7200, 9600, 14400, |
| 19200, 28800, 38400, 57600, 115200. |
|
|
Stop Bits | Number of stop bits for Passthrough port (1 or 2). |
|
|
Parity | None, Even, Odd. |
|
|
RTS Control | Force Off, Force On or Automatic. If automatic, the control will be |
| on when Passthrough is active. DTR and RTS are not available for |
| COM2. Under no conditions are RTS or DTR controls passed |
| through |
| not available for COM2. |
|
|
DTR Control | Force Off, Force On or Automatic. If automatic, the control will be |
| On when Passthrough is active. Not available on COM2. See note |
| above. |
|
|
42 | © 2007 VBrick Systems, Inc. |