MPEG-2 Configuration

 

 

 

 

 

 

 

 

 

SNMP Trap Version

Select Version number.

 

 

 

 

 

Trap User Name

User assigned trap name.

 

 

 

 

 

Authentication Password

Enter password. Cannot exceed 20 characters. May include any

 

 

 

combination of alphanumeric characters but only the following

 

 

 

special characters: ~ ! # $ ^ * + & % [ ] { } < > See Table 5 on

 

 

 

page 93 for defaults.

 

 

 

 

 

Authentication Protocol

Select protocol: MD5 or SHA to validate the transaction

 

 

 

between a given host and client

 

 

 

 

 

Privacy Password

Required. Hides traffic using DES encryption.

 

 

 

 

 

Security Level

No Authentication, No Privacy (default).

 

 

 

No Privacy.

 

 

 

Authentication and Privacy.

 

 

 

 

 

Table 4. Trap Summary Tables

 

 

 

 

 

Number

Event Description

 

 

 

 

1

There is loss of video input on slot1 Encoder.

 

 

 

2

The loss of video input on slot1 Encoder failure has cleared.

 

 

 

3

There is loss of video input on slot2 Encoder.

 

 

 

4

The loss of video input on slot2 Encoder failure has cleared.

 

 

 

5

The box has started up in Run mode.

 

 

 

6

The box has started up in Diagnostics mode.

 

 

 

7

The box has started up in Limited Run mode.

 

 

 

8

The box has received a reset request from an administrator.

 

 

 

9

There is a fan failure.

 

 

 

10

The fan failure is recovered.

 

 

 

11

The temperature of the unit is out of range. Will be sent when the unit's internal

 

 

temperature becomes too high or too low.

 

 

 

12

The temperature out of range condition has cleared.

 

 

 

13

The 24 volts power supply failed.

 

 

 

14

The 24 volts power supply failure has cleared.

 

 

 

15

The 12 volts power supply failed.

 

 

 

16

The 12 volts power supply failure has cleared.

 

 

 

17

The 5 volts power supply failed.

 

 

 

18

The 5 volts power supply failure has cleared.

 

 

 

19

The 3.3 volts power supply failed.

 

 

 

20

The 3.3 volts power supply failure has cleared.

 

 

 

21

The 2.5 volts power supply failed.

 

 

 

 

VBrick MPEG-2 Appliance Admin Guide

47

Page 55
Image 55