Passthrough State: Responder

Operational State

Describes the current status of a Passthrough connection, including

 

error conditions, if any. Refer to the Network Status Section. This will

 

display "Active" if in Passthrough mode.

 

 

COM Interface

Describes the COM interface connector. (RS422/485 options are

Type

displayed only if main board has a Part Number ending in xxx3. See

 

Status: User Information > Main Board.)

 

• RS232 – standard RS-232 serial port connector.

 

• RS422/485 – RS-422/485 4-wire serial port connector.

 

• RS422/485 (Terminated) – RS-422/485 terminated.

 

 

Passthrough State: Responder

Baud Rate

Rate can be set to the following (Default = 9600): 110, 300, 600, 1200,

 

2400, 3600, 4800, 7200, 9600, 14400, 19200, 28800, 38400, 57600,

 

115200.

 

 

Stop Bits

Number of stop bits for Passthrough port (1 or 2).

 

 

Parity

None, Even, Odd.

 

 

RTS Control

Force Off, Force On or Automatic. If automatic, the control will be

 

on when Passthrough is active. DTR and RTS are available for COM2

 

only for those VBrick models whose last digit is 3 or higher. Under no

 

conditions are RTS or DTR controls passed through end-to-end. All

 

control handling is local.

 

 

DTR Control

Force Off, Force On or Automatic. If automatic, the control will be

 

On when Passthrough is active. See note above.

 

 

Operational State

Describes the current status of a Passthrough connection, including

 

error conditions, if any. Refer to the Network Status Section. This will

 

display "Active" if in Passthrough mode.

 

 