VBrick Systems VB5000, VB6000, VB4000 manual Status Network Status Codec

Models: VB6000 VB5000 VB4000

1 128
Download 128 pages 47.3 Kb
Page 71
Image 71
Status: Network Status

Status

DHCP Status

Dynamic Host Configuration Protocol – Ethernet models only.

 

Enabled/Disabled. Possible DHCP Status values:

 

Disabled

 

Succeeded

 

Failed

 

• Succeeded without Subnet Value – No subnet value given;

 

 

generated from IP address.

 

• Succeeded with Invalid Subnet Value – Invalid subnet value given;

 

 

generated from IP address.

 

• Failed over Backplane – Device number invalid in backplane.

 

• Failed, Invalid Device Unit – Network interface device number

 

 

invalid.

 

• Failed Invalid Cookie – Network interface inoperable.

 

• Failed, Bind Failed – DHCP server not available or appliance not

 

 

connected to network.

 

• Failed, Out of Memory – Appliance is out of memory. Indicates a

 

 

severe condition.

 

• Failed, Parameter Get Failed – Couldn't retrieve a DHCP

 

 

parameter needed/requested.

 

• Failed, Invalid Boot File – Invalid boot file specified. Indicates a

 

 

severe condition.

 

• Failed, Invalid Retrieved IP address assigned by the server is not a

 

 

valid unicast address.

 

 

Temperature

Displays the temperature of the appliance (Celsius).

 

 

Fan State

Displays the state of the fan as Not Operational, High or Low.

 

 

Battery Status

OK or Failed.

 

 

Overloaded Count

Provides a count of the number of times the box has entered the

 

Overloaded state.

 

 

CPLD version

Displays the Main Board programmable device version number.

 

 

Boot Revision

Displays the date of the last boot revision.

 

 

Code Revision

Displays the date of the last code revision.

 

 

Release Revision

Displays the release version number.

 

 

CPU Utilization%

The percentage of the Central Processor in use at this time.

 

 

Power Supply

Displays the measured voltages present and provided to the VBrick

Voltage

(24V, 12V, 5V, 3.3V 2.5V). The tolerance range for 24V is minimum

 

18V to maximum 25V. The range for all other voltages is plus or

 

minus 5%.

 

 

 

Status: Network Status

Status: Network Status > Codec

This menu allows the user to view various network-level conditions.

VBrick MPEG-2 Appliance Admin Guide

63

Page 71
Image 71