Maintenance: Default All Configuration

Total System Up Time

Displays the total time that the unit has been powered up.

Note The Device Information table creates a date and time stamp for every power or reset event. When SNTP is enabled, the unit must reboot to synchronize time with the SNTP server time. If the time moves dramatically forward (or backward), a discontinuity may appear in the device table because of the SNTP time correction.

Maintenance: Default All Configuration

This menu allows the user to default all the configuration parameters of the VBrick.

Default All

Sets all parameters except IP address, Subnet Mask, Gateway IP, User

 

Names, Passwords and System Date Time.

 

 

Factory Defaults

Sets all parameters including IP Address and associated settings to

 

factory defaults with the exception of System Date and Time.

 

 

Maintenance: Read/Write Configuration

Maintenance: Read/Write > Read From Device

The Read/Write Configuration page allows you to read configuration parameters from the VBrick to a file, as well as write configuration parameters from a file to the VBrick. The file is an .xml file and Internet Explorer is the assumed browser.

Note The VBrick appliance the .xml file is read from, and VBrick appliance the .xml file is written to, must be running the same version of code.