Xantrex Technology XFR 2800 manual Installation, Terminal, Name, Function

Models: XFR 2800

1 90
Download 90 pages 12.58 Kb
Page 56
Image 56
(Shown with local sense jumpers connected.)

Installation

Local and Remote Sensing

.

Figure 2.11J10 Sense Connector

(Shown with local sense jumpers connected.)

Table 2.5 Rear Panel J10 Sense Connector Terminals and Functions

Terminal

Name

Function

J10-1

Return Sense (–SNS)

Remote negative sense connection.

 

 

Default connection to terminal 2.

J10-2

Negative Output (Return or RTN)

Connected internally to negative bus

 

 

bar.

 

 

 

J10-3

N/C

No connection.

 

 

 

J10-4

Positive Output (+OUT)

Connected internally to positive bus

 

 

bar.

 

 

 

J10-5

Positive Sense (+SNS)

Remote positive sense connection.

 

 

Default connection to terminal 4.

54

Operating Manual for XFR 2.8kW Series Power Supply

Page 56
Image 56
Xantrex Technology XFR 2800 manual Installation, Terminal, Name, Function, Shown with local sense jumpers connected