Remote Operation
Remote Analog Programming of Output Voltage and Current Limit
4.Connect the programming source(s) to the mating J2 connector as shown in Figure 4.1, observing the correct polarity for voltage sources. Ensure that the mating connector is plugged securely into the rear panel connector.
5.Set the programming sources to the desired levels and turn the power supply ON. The REM LED turns on.
6.Adjust the external programming source to change the power supply’s output.
Notes:
1.Switches SW1 to SW4 can be set to their defaults (all open) unless otherwise specified in Table 4.2. Switches
2.Resetting switches
3.Any of the eight switches on SW1 is OFF (OPEN) when it has been flipped up to break contact, ON (CLOSED) when flipped down to close contact.
4.The control circuits have been designed to allow you to set output voltage and current up to 5% over the