Remote Operation
Remote Analog Programming of Output Voltage and Current Limit
Table 4.2 Power Supply Settings for Different Programming Sources
Output | Output Current Limit Programming Source |
|
| ||
Voltage |
|
|
|
|
|
|
|
|
| None (Front | |
Programming | |||||
Source |
|
|
|
| Panel Control) |
SW1: | SW1: | SW1: | SW1: | SW1: | |
| set 3 and 4 | set 3 open. | set 2 closed, 3 | set 2 closed, 3 | set 3 open. |
| open. | J2: jumper 1 to | and 4 open. | open. | J2: jumper 1 to |
| J2: jumper 1 to | 3 and 2 to 3. | J2: jumper 1 to | J2: jumper 1 to | 3. |
| 3 and 2 to 3. |
| 3 and 2 to 3. | 3 and 2 to 3. |
|
|
|
|
|
|
|
SW1: | SW1: | SW1: | SW1: | SW1: | |
| set 4 open. | default settings. | set 2 closed, | set 2 closed. | default settings. |
| J2: jumper 1 to | J2: jumper 1 to | 4 open. | J2: jumper 1 to | J2: jumper 1 to |
| 3 and 2 to 3. | 3 and 2 to 3. | J2: jumper 1 to | 3 and 2 to 3. | 3. |
|
|
| 3 and 2 to 3. |
|
|
SW1: | SW1: | SW1: | SW1: | SW1: | |
| set 1 closed, | set 1 closed, | set 1 and 2 | set 1 and 2 | set 3 open, |
| 3 and 4 open. | 3 open. | closed, | closed, 3 open. | 1 closed. |
| J2: jumper 1 to | J2: jumper 1 to | 3 and 4 open. | J2: jumper 1 to | J2: jumper 1 to |
| 3 and 2 to 3. | 3 and 2 to 3. | J2: jumper 1 to | 3 and 2 to 3. | 3. |
|
|
| 3 and 2 to 3. |
|
|
SW1: | SW1: | SW1: | SW1: | SW1: | |
| set 1 closed, | set 1 closed. | set 1 and 2 | set 1 and 2 | set 1 closed. |
| 4 open. | J2: jumper 1 to | closed, 4 open. | closed. | J2: jumper 1 to |
| J2: jumper 1 to | 3 and 2 to 3. | J2: jumper 1 to | J2: jumper 1 to | 3. |
| 3 and 2 to 3. |
| 3 and 2 to 3. | 3 and 2 to 3. |
|
None (Front | SW1: | SW1: | SW1: | SW1: | SW1: |
Panel Control) | set 4 open. | default settings. | set 2 closed, | set 2 closed. | default settings. |
| J2: jumper 2 to | J2: jumper 2 to | 4 open. | J2: jumper 2 to | J2: no jumper. |
| 3. | 3. | J2: jumper 2 to | 3. |
|
|
|
| 3. |
|
|
|
|
|
|
|
|
76 | Operating Manual for XFR 2.8kW Series Power Supply |