Xantrex Technology XFR 2800 manual

Models: XFR 2800

1 90
Download 90 pages 12.58 Kb
Page 66
Image 66
1.If switch SW1-7 is ON but there is no signal applied, the S/D LED turns on and the power supply will not provide an output until the HIGH signal level is applied.

Local Operation

Using the Shutdown Function

Table 3.2 Switch Settings for Shutdown Circuit Logic

Switch SW1-7 Setting

Source Signal

Signal Level

Supply Output

S/D LED

OFF (OPEN)

2-15 V

HIGH

OFF

ON

(Active low, default)

 

 

 

 

0-0.4 V

LOW

ON

OFF

 

 

 

 

 

 

ON (CLOSED)

2-15 V

HIGH

ON

OFF

(Active high)

 

 

 

 

0-0.4 V

LOW

OFF

ON

 

 

 

 

 

 

Notes:

1.If switch SW1-7 is ON but there is no signal applied, the S/D LED turns on and the power supply will not provide an output until the HIGH signal level is applied.

2.Any of the eight switches on SW1 is OFF (OPEN) when it has been flipped up to break contact, ON (CLOSED) when flipped down to close contact.

64

Operating Manual for XFR 2.8kW Series Power Supply

Page 66
Image 66
Xantrex Technology XFR 2800 manual