Additional

Features and Specifications

Specifications

Additional

Features

Switching Frequency

nominal 31 kHz (62 kHz output ripple).

 

 

Output Hold-up Time

Greater than 10 ms with interruption of AC line,

 

for nominal AC input and full load.

 

 

Maximum Voltage Differential from

±600 Vdc

either output to safety ground

 

 

 

Insulation Resistance

Input to chassis: >30 M, with 500 Vdc;

 

Output to chassis: >20 M, with 1000 Vdc.

 

 

Isolation Voltage

Input to output: 1350 Vac

 

 

Remote

Programming

and

Monitoring

Remote Start/Stop and Interlock

2.5-15 V signal or TTL-compatible input,

 

selectable logic. TTL input impedance: 2 k (in

 

series with one diode drop).

 

 

Remote Analog Programming (Full

Voltage and current programming inputs

Scale Input)

(source must be isolated): 0-5 k, 0-10 k

 

resistances; 0-5 V, 0-10 V (default) voltage

 

sources. Input impedance (V and I):

 

approximately 100 k.

 

 

Remote Monitoring

Output voltage and current: 0-5 V, 0-10 V

 

(default);

 

Output impedance (V and I): approximately

 

221 .

 

Output short circuit current: approximately

 

50 mA.

 

 

Remote Programming and

1% zero to full scale output for the default

Monitoring Accuracy

range.

 

 

Maximum Remote Sense Line Drop

5 V/line (Line drop is subtracted from total voltage

Compensation

available at supply output.)

 

 

Optional Isolated Program and

0-5 V (ISOL interface); input impedance: 200 k;

Readback (V&I)

output impedance: 221 .

 

 

Optional Digital Control

RS-232, GPIB interfaces

 

 