Xantrex Technology XFR 2800 manual Functional Tests, Voltage Mode Operation Check

Models: XFR 2800

1 90
Download 90 pages 12.58 Kb
Page 45
Image 45

Installation

Functional Tests

Functional Tests

Equipment Required

These functional test procedures include power-on and front panel function checks as well as voltage and current mode operation checks. Refer to front and rear panel diagrams in “Front Panel Controls” on page 17 and “Rear Panel Connectors and Switch” on page 18.

Digital voltmeter (DVM) rated better than 0.5% accuracy.

DC shunt 1 mV/A (±0.25%) with connecting wire. The recommended current ratings for the DC shunt and the wire must be at least 10% more than the output current of the power supply.

Power-on Check

1.Ensure that the AC power switch is in the OFF position.

2.Ensure that the output sense lines are connected in the default configuration. (The local sense lines are connected between terminals 1 and 2 and between terminals 4 and 5 on the J10 sense connector as shown on the rear panel diagram in Figure .)

3.Turn the voltage and current controls fully counter-clockwise.

4.Connect the unit to an AC outlet.

5.Turn the front panel AC power switch to ON.

After a short, power-on delay, the front panel digital meters light up and the green voltage mode LED turns on. Both voltmeter and ammeter displays read zero.

Voltage Mode

Operation

Check

1.Ensure the voltage and current controls on the front panel are turned fully counter-clockwise.

2.Connect a DVM to the output terminals on the rear panel, observing correct polarity.

3.Turn the current control a 1/2-turn clockwise. Slowly turn the voltage control clockwise and observe both the front panel voltmeter and the DVM.

4.Compare the DVM reading with the front panel voltmeter reading to verify the accuracy of the internal voltmeter. Both readings should be the same. The minimum control range is from zero to the maximum rated output for the power supply model. The voltage mode LED turns on.

5.Turn the front panel AC power switch to OFF.

Release 2.1

43

Page 45
Image 45
Xantrex Technology XFR 2800 manual Functional Tests, Voltage Mode Operation Check