Xantrex Technology XFR 2800 manual Supplies for Split Supply Operation

Models: XFR 2800

1 90
Download 90 pages 12.58 Kb
Page 69
Image 69
Supplies for

Local Operation

Using Multiple Supplies

Sensing for Parallel Operation Use default local sensing to enhance power sharing between units, as the impedance of the load lines will tend to correct for current imbalance. If you use remote sensing at the load for better voltage regulation, one supply always operates in current limit mode and supplies most of the power.

Figure 3.3 Parallel Operation of Multiple Supplies

(Local sense lines shown are default J10 connections.)

Configuring Split supply operation uses two power supplies to obtain two positive voltages with Multiple a common ground, or to obtain a positive-negative supply.

Supplies for

Split Supply

Operation

Release 2.1

67

Page 69
Image 69
Xantrex Technology XFR 2800 manual Supplies for Split Supply Operation