PREINSTALLATION
Environmental/electrical requirements
Your DocuPrint 96/DocuPrint 96MX LPS has important environmental and electrical requirements that must be accommodated. These requirements are summarized in the table below. For further details on electrical requirements, refer to the following voltage charts and wiring diagrams.
Table
| electrical requirements | |
|
|
|
Environmental requirements |
|
|
|
|
|
Operating temperature | Recommended: | 72° F ± 4° F/22° C ± 2° C |
| Minimum: | 60° F/15.5° C |
| Maximum: | 80° F/29.5° C |
|
|
|
Humidity | Recommended: 4 | 45% ± 10% |
| Minimum: | 15% |
| Maximum: | 85% |
|
|
|
Altitude | Normal: | Up to 6,000 feet/1830 m above sea level |
| Maximum: | 9,000 feet/2743 m above sea level |
|
|
|
Heat dissipation |
|
|
|
|
|
System controller | Operating: | 4,354 Btu per hour |
| Standby: | 2,485 Btu per hour |
|
|
|
Peripheral cabinet (fully configured) | Operating: | 3,195 Btu per hour |
| Standby: | 1,775 Btu per hour |
|
|
|
Printer | Operating: | 28,140 Btu per hour |
| Standby: | 4,454 Btu per hour |
|
|
|
System controller | U.S. and Canada, 60 | 208/240 VAC (1 phase) or 208/220 VAC |
| Hz: | (2 phase) |
|
| 15 amp service |
|
| NEMA |
|
| KVA 1.1 (operating) |
| International, 50 Hz: | 200/240 VAC |
|
| 15 amp service; |
|
| Power connector per local codes |
|
|
|
XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE |