PREINSTALLATION
Table
| electrical requirements (continued) | |
|
|
|
Environmental requirements |
|
|
|
|
|
Printer | U.S. and Canada, | 120/240 VAC or |
| 60Hz: | 120/208 VAC; |
|
| 50 amp service; |
|
| NEMA |
|
| KVA 7.3 (operating) |
| International, 50 Hz | 380, 400, 415 VAC |
| (WYE): | (3 phase, 5 wire); |
|
| 20 amp service (WYE) |
| International, 50 Hz | 220, 230, 240 VAC (3 phase, 4 wire); |
| (DELTA): | 30 amp service (DELTA) |
|
| |
|
|
|
Audible noise | Standby: | Continuous: 52 dB (A) |
|
| Impulse: N/A |
| Operating: | Continuous: 67dB (A) |
|
| Impulse: 72dB (A) |
|
|
|
Optional peripheral cabinet | U.S. and Canada, | 208/240 VAC (1 phase) or |
| 60Hz: | 208/220 VAC (Line 1 to line 2); |
|
| |
|
| 15 amp service; |
|
| |
|
| ANSI C73, 20R |
|
| KVA .9 in both standby and operating |
| International, 50 Hz: | 200/230 VAC (1 phase); |
|
| 15 amp service |
|
|
|
Optional bypass transport | The power requirements for the bypass transport module are all | |
| satisfied by the DocuPrint 96/DocuPrint 96MX LPS printer module. | |
|
| |
Agency certification | UL, CSA, CE Mark, EC 950, VDE 0871 (Level AQ) and 0875, EEC | |
| 82/499, and CISPR 22 Class A. | |
|
|
|
XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE |