84Default Parameter Settings Parallel Port Setup

Parallel Port Setup

5

1

Default

Disable Parallel Port Signaling

0

Min

 

1

Max

 

Pins 12 and 15 on the parallel port signal paper out and error. However, in an unattended kiosk you may not want this because it causes the host computer to stop communicating, and the operating system may display a warning or error message on the kiosk screen.

By disabling the hardware signals, the kiosk software can for example use status commands to find out paper level and alert appropriate personnel when the level is low, then close the kiosk when paper is out.

<ESC>&P<5><0>

Paper out and error signals are active and enabled.

<ESC>&P<5><1>

Paper out and error signals are disabled

Note • When enabled, the hardware signal on pin 12 and 15 will block all communication until the error is corrected. This means that it will be impossible to ask for status.

P1002902-002

TTP 2000 Technical Manual