Agilent Technologies 5951-2827 manual 6060B 6063B, Regulation Constant Resistance Mode Ranges

Page 11

Table 1-1. Specifications (continued)

DERATED CURRENT DETAIL

6060B

6063B

CONSTANT CURRENT MODE

Ranges

Low Range:

High Range:

Accuracy (after 30 sec wait):

Regulation:

CONSTANT RESISTANCE MODE Ranges

Low Range:

Middle Range:

High Range:

Accuracy

Low Range:

Middle and High Ranges:

CONSTANT VOLTAGE MODE

Range:

Accuracy:

Regulation:

0 to 6 A

0 to 60 A

±0.1% ± 75 mA both ranges

10 mA both ranges

0.033 to 1 W

1 to 1000 W

10 to I 0,000 W

±0.8% ± 8 mW with ³ 6 V at input

±0.3% ± 8 mS with ³ 6 V at input

0 to 60 V

± 0.1% ± 50 mv

10 mV (remote sense),

40 mV (local sense)

0 to 1 A

0 to 10 A

±0.15% ± 10 mA both ranges

8 mA both ranges

0.20to 24 W 24 to 10,000 W 240 to 50,000 W

± 0.8% ± 200 m W with ³ 1 A at input

±0.3% ± 0.3 mS with ³ 24 V at input

0 to 240 V

±0.12% ± 120 mV

10 mV (remote sense)

40 mV (local sense)

TRANSIENT OPERATION

Modes:

Continuous Mode

Freq Range:

Freq Accuracy:

Duty Cycle Range:

Duty Cycle Accuracy:

Pulsed Mode

Pulse Width:

Continuous, pulsed, or toggled

0.25Hz to 10 kHz

3%

3% to 97% (0.25 Hz to 1 kHz);

6% to 94% (1 kHz to 10 kHz)

6% of setting ± 2%

50 ms ± 3% minimum; 4 s ± 3% maximum

General Information 11

Image 11
Contents Operating Manual Agilent Part No Microfiche Part No Updated AprilCertification Safety Summary Manufacturer’s Declaration Safety SummarySymbol Description HerstellerbescheinigungPrinting History Table of Contents Calibration Local OperationRemote Operation Considerations for Operating in Constant Resistance Mode General Information What’s In This ManualReader Path OptionsSpecifications Safety Requirements6060B 6063B Regulation Constant Resistance Mode RangesModes Continuous Mode Pulsed ModeCurrent Readback Temperature Coefficient Supplemental Characteristics 6060B 6063BResolution Bandwidth Maximum Readback CapabilityRate # High Range Step Low Range Step Transition Time Supplemental CharacteristicsMaximum VA Peak Inrush Current 2.5 a typical Current Slew RateModel 6063B Range Transient Current Level Resistance Slew RateOvershoot Width 6060B 6063B 10%With unit on With unit offPage Operation Overview IntroductionFront Panel Description Remote ProgrammingModes of Operation Local/Remote ControlProgrammable Features Constant Current CC ModeSoftware Current Limit Triggered Current LevelImmediate Resistance Level Constant Resistance CR ModeSlew Rate Transient Resistance Level Constant Voltage CV ModeTriggered Resistance Level Transient Operation Immediate Voltage LevelTriggered Voltage Level Transient Voltage LevelPulsed Transient Operation Hpsl Command DescriptionSelects the external trigger input source Selects the external trigger inputSelects pulsed transient operation Sets pulse width to 1 millisecondSlew Rate And Minimum Transition Time Triggering a preset levelTriggering a transient pulse TogglingRisetime Transition Limitation Input Current, Voltage, and Power MeasurementTransition Times and Slew Rates Short On/OffStatus Reporting Saving and Recalling SettingsReading Remote Programming Errors Input On/OffOvercurrent Protection FeaturesResetting Latched Protection OvervoltageReverse Voltage Control ConnectorOverpower OvertemperatureExternal Programming Input FaultMonitor Outputs Port On/Off Inspection Check Line Voltage Location and CoolingTurn-On Checkout Line Voltage Fuse Agilent Part No Voltage Select SwitchesTurn-On/Selftest Connect The Power CordGpib Errors Input Errors Display Description ErrorController Connection Power TestGpib Connector AWG Rear Panel Connectors and SwitchesWire Size Strip back Gpib AddressInput Binding Post Control Connector Common Pins 3+S and -S IM and VMSense Switch Trigger ConnectorApplication Connections Zero-Volt Loading Connections Maximum Wire Lengths to Limit Voltage DropsParallel Connections 11. Local Sensing 13. Parallel Operation Page Local Operation Front Panel Controls and Indicators DescriptionControls and Indicators Description Function Keys Local Control Overview Turning the Input On/Off Using The Function Keys∙ Short on Recommended Programming Sequence Key Display Setting the Mode of OperationSetting CC Values CC Programming Ranges FunctionExamples Setting CR Values Examples Setting CV Values Function Key Display Range of Values Continuous Pulse Train Programming RangesShorting The Input Using The System KeysDisplaying Error Codes Setting The Electronic Load’s Gpib AddressChanging Wake-up Settings Factory Default Settings Function 6060B 6063BRecalling the Factory Default Values Enter Enter/Output StatementsGpib Address OutputOutput 705 MEASCURR? Sending a Remote CommandRemote Programming Commands Getting Data BackSlew Rates ModesRanges Transient levelsRemote Programming Flowchart Sheet Remote Programming Flowchart Sheet CR Mode Example CC Mode ExampleCV Mode Example Pulsed Transient Operation Example Continuous Transient Operation ExampleConstant Current CC Hpsl Command Short FormOutput 705TRAN on Output 705INPUT on Remote Programming Ranges FunctionTransient Operation Constant Resistance CR6060B Constant Voltage CVPage Equipment Required for Calibration Equipment Characteristics Recommended ModelExample Programs Equipment RequiredCalibration Commands Example Program Calibration FlowchartsCalibration Information 6060B 6063B Supply Shunt Values SettingsCalibration Flowchart Calibration Flowchart Calibration Flowchart END if Program ListingPause WaitPrint Voltage Calibration Pause SubendElse Line ExplanationPage Considerations For Operating In Constant Resistance Mode Considerations For Operating In Constant Resistance ModeConsiderations For Operating In Constant Resistance Mode Index IndexIndex 24, 25, 26 Index Agilent Sales and Support Office Agilent Sales and Support OfficesManual Updates