Agilent Technologies 5951-2826, 5951-2827 manual Table of Contents

Page 6

 

Table of Contents

 

1.

General Information

 

 

What’s in this Manual

9

 

Reader Path

9

 

Options

9

 

Safety Requirements

10

 

Specifications

10

2.

Operation Overview

 

 

Introduction

19

 

Front Panel Description

19

 

Remote Programming

19

 

Local/Remote Control

20

 

Programmable Features

20

 

Modes of Operation

20

 

Constant Current CC (Mode)

20

 

Constant Resistance (CR) Mode

22

 

Constant Voltage (CV) Mode

23

 

Transient Operation

24

 

Triggered Operation

27

 

Slew Rate and Minimum Transition Time

27

 

Input Current, Voltage, and Power Measurement

28

 

Short On/Off

29

 

Input On/off

30

 

Saving and Recalling Settings

30

 

Reading Remote Programming Errors

30

 

Status Reporting

30

 

Protection Features

31

 

Resetting Latched Protection

31

 

Overvoltage

31

 

Overcurrent

31

 

Overpower

32

 

Overtemperature

32

 

Reverse Voltage

32

 

Control Connector

32

 

Remote Sensing

32

 

Monitor Outputs

33

 

External Programming Input

33

 

Fault

33

 

Port On/Off

34

3.

Installation

 

 

Introduction

35

 

Inspection

35

 

Location and Cooling

36

 

Turn-On Checkout

36

 

Check Line Voltage

36

 

Connect the Power Cord

38

 

Turn-On/Selftest

38

 

Power Test

37

6

Image 6
Contents Agilent Part No Microfiche Part No Updated April Operating ManualCertification Safety Summary Herstellerbescheinigung Safety SummarySymbol Description Manufacturer’s DeclarationPrinting History Table of Contents Local Operation Remote OperationCalibration Considerations for Operating in Constant Resistance Mode Options What’s In This ManualReader Path General InformationSafety Requirements SpecificationsPulsed Mode Regulation Constant Resistance Mode RangesModes Continuous Mode 6060B 6063BCurrent Readback Supplemental Characteristics 6060B 6063B ResolutionTemperature Coefficient Maximum Readback Capability BandwidthCurrent Slew Rate Supplemental CharacteristicsMaximum VA Peak Inrush Current 2.5 a typical Rate # High Range Step Low Range Step Transition TimeResistance Slew Rate OvershootModel 6063B Range Transient Current Level With unit off 6060B 6063B 10%With unit on WidthPage Remote Programming IntroductionFront Panel Description Operation OverviewConstant Current CC Mode Local/Remote ControlProgrammable Features Modes of OperationTriggered Current Level Software Current LimitConstant Resistance CR Mode Slew RateImmediate Resistance Level Constant Voltage CV Mode Triggered Resistance LevelTransient Resistance Level Transient Voltage Level Immediate Voltage LevelTriggered Voltage Level Transient OperationHpsl Command Description Pulsed Transient OperationSets pulse width to 1 millisecond Selects the external trigger inputSelects pulsed transient operation Selects the external trigger input sourceToggling Triggering a preset levelTriggering a transient pulse Slew Rate And Minimum Transition TimeInput Current, Voltage, and Power Measurement Risetime Transition LimitationShort On/Off Transition Times and Slew RatesInput On/Off Saving and Recalling SettingsReading Remote Programming Errors Status ReportingOvervoltage Protection FeaturesResetting Latched Protection OvercurrentOvertemperature Control ConnectorOverpower Reverse VoltageFault Monitor OutputsExternal Programming Input Port On/Off Inspection Location and Cooling Turn-On CheckoutCheck Line Voltage Voltage Select Switches Line Voltage Fuse Agilent Part NoError Connect The Power CordGpib Errors Input Errors Display Description Turn-On/SelftestPower Test Gpib ConnectorController Connection Gpib Address Rear Panel Connectors and SwitchesWire Size Strip back AWGInput Binding Post Control Connector IM and VM Pins 3+S and -S CommonTrigger Connector Sense SwitchApplication Connections Maximum Wire Lengths to Limit Voltage Drops Parallel ConnectionsZero-Volt Loading Connections 11. Local Sensing 13. Parallel Operation Page Front Panel Controls and Indicators Description Local OperationControls and Indicators Description Function Keys Local Control Overview Using The Function Keys ∙ Short onTurning the Input On/Off Recommended Programming Sequence CC Programming Ranges Function Setting the Mode of OperationSetting CC Values Key DisplayExamples Setting CR Values Examples Setting CV Values Continuous Pulse Train Programming Ranges Function Key Display Range of ValuesUsing The System Keys Shorting The InputSetting The Electronic Load’s Gpib Address Displaying Error CodesFactory Default Settings Function 6060B 6063B Changing Wake-up SettingsRecalling the Factory Default Values Output Enter/Output StatementsGpib Address EnterGetting Data Back Sending a Remote CommandRemote Programming Commands Output 705 MEASCURR?Transient levels ModesRanges Slew RatesRemote Programming Flowchart Sheet Remote Programming Flowchart Sheet CC Mode Example CV Mode ExampleCR Mode Example Continuous Transient Operation Example Pulsed Transient Operation ExampleRemote Programming Ranges Function Hpsl Command Short FormOutput 705TRAN on Output 705INPUT on Constant Current CCConstant Voltage CV Constant Resistance CR6060B Transient OperationPage Equipment Required Equipment Characteristics Recommended ModelExample Programs Equipment Required for CalibrationCalibration Commands Calibration Flowcharts Example ProgramSupply Shunt Values Settings Calibration Information 6060B 6063BCalibration Flowchart Calibration Flowchart Calibration Flowchart Wait Program ListingPause END ifPause Subend Print Voltage CalibrationElse Explanation LinePage Considerations For Operating In Constant Resistance Mode Considerations For Operating In Constant Resistance ModeConsiderations For Operating In Constant Resistance Mode Index IndexIndex 24, 25, 26 Index Agilent Sales and Support Offices Agilent Sales and Support OfficeManual Updates