Agilent Technologies 5951-2827, 5951-2826 manual Local Operation, Remote Operation, Calibration

Page 7

 

Table of Contents (continued)

 

 

Controller Connection

39

 

GPIB Connector

39

 

GPIB Address

40

 

Rear Panel Connectors and Switches

40

 

Input Binding Posts

40

 

Control Connector

41

 

Trigger Connector

43

 

Sense Switch

43

 

Application Connections

44

 

Wiring Considerations

44

 

Local Sense Connections

44

 

Remote Sense Connections

44

 

Parallel Connections

45

 

Zero-Volt Loading Connections

45

4.

Local Operation

 

 

Introduction

49

 

Local Control Overview

52

 

Using The Function Keys

53

 

Turning the Input On/Off

53

 

Setting the Mode of Operation

55

 

Setting CC Values

55

 

Setting CR Values

57

 

Setting CV Values

59

 

Transient Operation

60

 

Shorting the Input

61

 

Resetting Latched Protection

61

 

Using The System Keys

61

 

Setting the GPIB Address

62

 

Displaying Error Codes

62

 

Saving and Recalling Settings

62

 

Changing "Wake-up" Settings

63

 

Recalling the Factory Default Values

64

5.

Remote Operation

 

 

Introduction

65

 

Enter/Output Statements

65

 

GPIB Address

65

 

Sending A Remote Command

66

 

Getting Data Back From The Electronic Load

66

 

Remote Programming Commands

66

 

CC Mode Example

70

 

CV Mode Example

70

 

CR Mode Example

70

 

Continuous Transient Operation Example

71

 

Pulsed Transient Operation Example

71

6.

Calibration

 

 

Introduction

75

 

Example Programs

75

 

Equipment Required

75

7

Image 7
Contents Operating Manual Agilent Part No Microfiche Part No Updated AprilCertification Safety Summary Manufacturer’s Declaration Safety SummarySymbol Description HerstellerbescheinigungPrinting History Table of Contents Remote Operation Local OperationCalibration Considerations for Operating in Constant Resistance Mode General Information What’s In This ManualReader Path OptionsSpecifications Safety Requirements6060B 6063B Regulation Constant Resistance Mode RangesModes Continuous Mode Pulsed ModeCurrent Readback Resolution Supplemental Characteristics 6060B 6063BTemperature Coefficient Bandwidth Maximum Readback CapabilityRate # High Range Step Low Range Step Transition Time Supplemental CharacteristicsMaximum VA Peak Inrush Current 2.5 a typical Current Slew RateOvershoot Resistance Slew RateModel 6063B Range Transient Current Level Width 6060B 6063B 10%With unit on With unit offPage Operation Overview IntroductionFront Panel Description Remote ProgrammingModes of Operation Local/Remote ControlProgrammable Features Constant Current CC ModeSoftware Current Limit Triggered Current LevelSlew Rate Constant Resistance CR ModeImmediate Resistance Level Triggered Resistance Level Constant Voltage CV ModeTransient Resistance Level Transient Operation Immediate Voltage LevelTriggered Voltage Level Transient Voltage LevelPulsed Transient Operation Hpsl Command DescriptionSelects the external trigger input source Selects the external trigger inputSelects pulsed transient operation Sets pulse width to 1 millisecondSlew Rate And Minimum Transition Time Triggering a preset levelTriggering a transient pulse TogglingRisetime Transition Limitation Input Current, Voltage, and Power MeasurementTransition Times and Slew Rates Short On/OffStatus Reporting Saving and Recalling SettingsReading Remote Programming Errors Input On/OffOvercurrent Protection FeaturesResetting Latched Protection OvervoltageReverse Voltage Control ConnectorOverpower OvertemperatureMonitor Outputs FaultExternal Programming Input Port On/Off Inspection Turn-On Checkout Location and CoolingCheck Line Voltage Line Voltage Fuse Agilent Part No Voltage Select SwitchesTurn-On/Selftest Connect The Power CordGpib Errors Input Errors Display Description ErrorGpib Connector Power TestController Connection AWG Rear Panel Connectors and SwitchesWire Size Strip back Gpib AddressInput Binding Post Control Connector Common Pins 3+S and -S IM and VMSense Switch Trigger ConnectorApplication Connections Parallel Connections Maximum Wire Lengths to Limit Voltage DropsZero-Volt Loading Connections 11. Local Sensing 13. Parallel Operation Page Local Operation Front Panel Controls and Indicators DescriptionControls and Indicators Description Function Keys Local Control Overview ∙ Short on Using The Function KeysTurning the Input On/Off Recommended Programming Sequence Key Display Setting the Mode of OperationSetting CC Values CC Programming Ranges FunctionExamples Setting CR Values Examples Setting CV Values Function Key Display Range of Values Continuous Pulse Train Programming RangesShorting The Input Using The System KeysDisplaying Error Codes Setting The Electronic Load’s Gpib AddressChanging Wake-up Settings Factory Default Settings Function 6060B 6063BRecalling the Factory Default Values Enter Enter/Output StatementsGpib Address OutputOutput 705 MEASCURR? Sending a Remote CommandRemote Programming Commands Getting Data BackSlew Rates ModesRanges Transient levelsRemote Programming Flowchart Sheet Remote Programming Flowchart Sheet CV Mode Example CC Mode ExampleCR Mode Example Pulsed Transient Operation Example Continuous Transient Operation ExampleConstant Current CC Hpsl Command Short FormOutput 705TRAN on Output 705INPUT on Remote Programming Ranges FunctionTransient Operation Constant Resistance CR6060B Constant Voltage CVPage Equipment Required for Calibration Equipment Characteristics Recommended ModelExample Programs Equipment RequiredCalibration Commands Example Program Calibration FlowchartsCalibration Information 6060B 6063B Supply Shunt Values SettingsCalibration Flowchart Calibration Flowchart Calibration Flowchart END if Program ListingPause WaitPrint Voltage Calibration Pause SubendElse Line ExplanationPage Considerations For Operating In Constant Resistance Mode Considerations For Operating In Constant Resistance ModeConsiderations For Operating In Constant Resistance Mode Index IndexIndex 24, 25, 26 Index Agilent Sales and Support Office Agilent Sales and Support OfficesManual Updates