Agilent Technologies E4400-90333 manual To -200 Execution Errors

Page 36

-299 to -200: Execution Errors

ESG Family Signal Generators

Settings conflict; The current data rate is not valid for this radio configuration. Data rate changed to the default rate.

The new radio configuration does not support the current data rate. The data rate changes to the default rate for the new radio configuration, which is 1× for F-FCH and 2× for F-SCH.

Settings conflict; Current file length does not have an integer number of symbols. User file size must have symbol boundary in order to transmit the file.

A user-defined file must end with a symbol. If it does not, transmission is aborted.

Settings conflict; The current paging indicator (PI) is not valid for 2400 bps data rate. The PI has been changed to 0, the default.

QPCH channel with a data rate of 2400 bps only supports up to 191 paging indicators. The PI has been set to 0 (default value) to remain valid for this data rate.

Settings conflict; The current RC or data rate does not support turbo coding. Turbo Coding has been turned off.

Either specification or hardware does not support turbo coding for this data rate. Turbo coding is now turned off. If you wish to use turbo coding, select a valid data rate and then turn turbo coding on. For F-SCH channels, data both rates below 14.4 kbps, and the highest data rates for each RC are not valid for turbo coding.

Settings conflict; Clipping not allowed for CDMA2000 reverse radio configs 1 and 2. Clipping set to 100%.

The clipping function is not available for the cdma2000 reverse link radio configs 1 and 2. The value is automatically reset to 100% (no clipping).

Settings conflict; Continuous protocol timeslots cannot be turned off.

A continuous protocol timeslot is switched off while in TETRA mode. When a continuous protocol has been selected for a timeslot in TETRA mode, all of the timeslots must be switched on.

34

Error Messages

Image 36
Contents Affix Label Here Part No. E4400-90333 Supersedes February Copyright 1999-2001 Agilent TechnologiesContents Introduction Error Message Format Error Message Types No Error To -400 Query Errors To -300 Device-Specific Errors Device has detected a failure during its self-test procedureNearest Agilent Technologies sales or service office Self-test for a particular power supply voltage has failed.Burst generator memory failed. Modulation data produced by 321Out of memory ARB communication failed Out of memory Could not copy current istate Out of memory Histogram display cannot function Out of memory Memory allocation error Out of memory Object Memory Area Lost. The meaning of this error is device-dependent Instrument is still functional320 315Non-volatile data saved by the *SAV? command has been lost Protected user data saved by the *PUD command has been lostAn error was detected in the device’s memory ValuesSystem error File Not Found To -200 Execution Errors When parsing a downloaded program is device-specific 285284 IllegalCommand header, or contained invalid header syntax Due to an error within the macro definition see Ieee 488.2Attempted. The definition of a math error is device-specific 276filename of was specified. This is not a legal filename An illegal memory subsystem name was used after the @File name error Illegal filename character File name not found SYSTEMFCDMA2KCHANFILE 254 Definition of what constitutes full media is device-specificCatalog. Afterwards, try again Try againSales or service office 252What constitutes missing media is device-specific 250Measurement accuracy is questionable Data corrupt or stale filename During the first power up after downloading new firmware into Algorithm. a potential cause is a failing backup batteryEeprom master copy if one exists. The system automatically 226223 Memory or related device-specific requirementsTo -200 Execution Errors Too much data User filter has too many symbols Data out of range Synthesizer Frequency out of bounds Data out of range value clipped to upper limit To -200 Execution Errors All digital modulation multicarriers must be the same format To -200 Execution Errors ESG Family Signal Generators Settings conflict Edge Bert requires Normal as Timeslot Type Settings conflict FM & PM not allowed Settings conflict GSM Bert requires Normal as Timeslot Type ESG Family Signal Generators Settings conflict I/Q & AM WB cannot be on at the same time ESG Family Signal Generators To -200 Execution Errors Used in RC1 Used in RC3 and 4 for channelTo -200 Execution Errors ESG Family Signal Generators For errors -221 through ErrorManual mode is on and therefore the instrument cannot sweep 220Have described the error that is stalling list/sweep 212Ignored 211Execution Error Cannot update FlexDG with Even Second Delay To -100 Command Errors Specified filename exceeds the maximum length Device cannot detect a more specific error Detect a more specific error150 148Header contains more than twelve characters see Ieee 488.2 110Command header error Syntax error 201 to 702 Device-Specific Errors Invalid file nameState file is not readable and the recall was aborted User has attempted to write to a read-only memory subsystemSynthesizer is unlocked. Service may be needed Internal error report to factoryInstrument’s output is unleveled 513 1 GHz Oscillator unlocked Calibration failure Dcfm DC overrange Reverse Power Protection RPP Tripped DSP FW download failed Demodulator board DSP times out Demodulator communication failed Option 300 DSP for Bert capability returns an error Configuration Error Option reconfiguration failed Configuration error Installed board not supported Configuration error OPTION, Invalid inconsistent license key Demodulator board has an invalid revision of DSP boot code Option UN7 hardware has an invalid revision of Fpga codeFpga download failed Demodulator board filter must have at least one coefficient specified Modulation must have at least two states specifiedfile is either corrupt or is not a FIR file Burst shape file is corrupted, or is not in the proper format