| ESG Family Signal Generators |
Settings conflict; EDGE BERT requires Normal as Timeslot Type.
An unsupported timeslot type was encountered. The measurement timeslot must be designated Normal.
Settings conflict; Enabled mod source conflicts with previously enabled mod source. Previous mod disabled.
The signal generator has three sources: INT, EXT1, and EXT2 that are shared by the FM1/PM1, AM1/AM2, FM2/PM2, pulse (INT and EXT2), and burst envelope (EXT1 only). Each source can be used by only one modulation at a time. If a source is being used by an active modulation, and a request for the source is made by another modulation, the first modulation is turned off and the second modulation is turned on.
Settings conflict; External burst cannot be on while using AM.
There is a hardware conflict for the burst envelope using the EXT1 source (I/Q menu) and AM1/AM2. The most recently requested modulation will be turned on, the previous modulation will be turned off.
Settings conflict; External data cannot be selected for multiple channels. PN9 is automatically selected for <CHANNEL NAME>.
The current hardware supports only one external data source at a time. The <CHANNEL NAME> data source has been changed to the default data source, PN9.
Settings conflict; FFCH/OCNS and QPCH cannot be on at the same time. QPCH has been tuned off.
QPCH is generated using both channel 3 and 4. Channel 3 has been turned on to generate FFCH or OCNS. Channel 4 can no longer generate QPCH. Therefore, QPCH must be turned off.
Settings conflict; FM1/PM1 value set less than FM2/PM2 value. FM2/PM2 changed to match FM1/PM1 value.
The deviation of FM2/PM2 must always be less than or equal to the deviation settings for FM1/PM1. This error will be reported to the queue when FM2/PM2 is enabled and FM1/PM1 is also enabled and an adjustment to either FM1/PM1 deviation causes the FM1 or PM1 deviation to be less than the FM2 or PM2 deviation. It will also be reported when FM1/PM1 is being turned on, and the last FM2/PM2 deviation setting is greater than the current FM1/PM1 deviation setting. In both cases the FM2/PM2 deviation will be adjusted to match the FM1/PM1 deviation.
36 | Error Messages |