Agilent Technologies E4400-90333 Have described the error that is stalling list/sweep, 212, 211

Page 49

ESG Family Signal Generators

-299 to -200: Execution Errors

 

Init ignored; Unable to sweep due to sweep being in an error

 

state. The sweep error should be fixed.

 

The number of list, power, and/or dwell points are in conflict, or a serious

 

system error has occurred in list/sweep. A previous error report should

 

have described the error that is stalling list/sweep.

-212

Arm ignored

 

An arming signal was received and recognized by the device but was

 

ignored.

-211

Trigger ignored

 

A GET, *TRG, or triggering signal was received and recognized by the

 

device, but was ignored because of device timing considerations. For

 

example, the device was not ready to respond.

-210

Trigger error

 

A GET,*TRG, or a triggering signal could not be executed due to an error.

-202

Settings lost due to rtl

 

A setting associated with a hard local control (see IEEE 488.2, 5.6.15) was

 

lost when the device changed to LOCS from REMS or to LWLS from

 

RWLS.

-201

Invalid while in local

 

A command is not executable while the device is in local mode due to a

 

hard local control (see IEEE 488.2, 5.6.1.5). For example, a device with a

 

rotary switch receives a message which would change the switch’s state,

 

but the device is in local so the message cannot be executed.

-200

Execution Error

 

For devices that cannot detect more specific errors, this code indicates only

 

that an execution error as defined in IEEE 488.2, 11.5.1.1.5 has occurred.

Execution Error; Cannot transmit paging message to FlexDG.

There is an error with the cdma2000 hardware. Try turning CDMA2000 mode off and on again to reset the card. If the problem persists, report this error to the nearest Agilent Technologies sales or service office.

Error Messages

47

Image 49
Contents Supersedes February Copyright 1999-2001 Agilent Technologies Affix Label Here Part No. E4400-90333Contents Introduction Error Message Format Error Message Types No Error To -400 Query Errors Device has detected a failure during its self-test procedure To -300 Device-Specific ErrorsSelf-test for a particular power supply voltage has failed. Nearest Agilent Technologies sales or service officeBurst generator memory failed. Modulation data produced by 321Out of memory ARB communication failed Out of memory Could not copy current istate Out of memory Histogram display cannot function Out of memory Memory allocation error Out of memory Object Memory Area Instrument is still functional Lost. The meaning of this error is device-dependent320 315Protected user data saved by the *PUD command has been lost Non-volatile data saved by the *SAV? command has been lostAn error was detected in the device’s memory ValuesSystem error File Not Found To -200 Execution Errors 285 When parsing a downloaded program is device-specific284 IllegalDue to an error within the macro definition see Ieee 488.2 Command header, or contained invalid header syntaxAttempted. The definition of a math error is device-specific 276An illegal memory subsystem name was used after the @ filename of was specified. This is not a legal filenameFile name error Illegal filename character File name not found SYSTEMFCDMA2KCHANFILE Definition of what constitutes full media is device-specific 254Catalog. Afterwards, try again Try again252 Sales or service officeWhat constitutes missing media is device-specific 250Measurement accuracy is questionable Data corrupt or stale filename Algorithm. a potential cause is a failing backup battery During the first power up after downloading new firmware intoEeprom master copy if one exists. The system automatically 226Memory or related device-specific requirements 223To -200 Execution Errors Too much data User filter has too many symbols Data out of range Synthesizer Frequency out of bounds Data out of range value clipped to upper limit To -200 Execution Errors All digital modulation multicarriers must be the same format To -200 Execution Errors ESG Family Signal Generators Settings conflict Edge Bert requires Normal as Timeslot Type Settings conflict FM & PM not allowed Settings conflict GSM Bert requires Normal as Timeslot Type ESG Family Signal Generators Settings conflict I/Q & AM WB cannot be on at the same time ESG Family Signal Generators To -200 Execution Errors Used in RC3 and 4 for channel Used in RC1To -200 Execution Errors ESG Family Signal Generators Error For errors -221 throughManual mode is on and therefore the instrument cannot sweep 220212 Have described the error that is stalling list/sweepIgnored 211Execution Error Cannot update FlexDG with Even Second Delay To -100 Command Errors Specified filename exceeds the maximum length Detect a more specific error Device cannot detect a more specific error150 148Header contains more than twelve characters see Ieee 488.2 110Command header error Syntax error Invalid file name 201 to 702 Device-Specific ErrorsUser has attempted to write to a read-only memory subsystem State file is not readable and the recall was abortedInternal error report to factory Synthesizer is unlocked. Service may be neededInstrument’s output is unleveled 513 1 GHz Oscillator unlocked Calibration failure Dcfm DC overrange Reverse Power Protection RPP Tripped DSP FW download failed Demodulator board DSP times out Demodulator communication failed Option 300 DSP for Bert capability returns an error Configuration Error Option reconfiguration failed Configuration error Installed board not supported Configuration error OPTION, Invalid inconsistent license key Option UN7 hardware has an invalid revision of Fpga code Demodulator board has an invalid revision of DSP boot codeFpga download failed Demodulator board Modulation must have at least two states specified filter must have at least one coefficient specifiedBurst shape file is corrupted, or is not in the proper format file is either corrupt or is not a FIR file