ESG Family Signal Generators |
-199 to -100: Command Errors
The instrument’s parser detected an IEEE 488.2 syntax error. Errors in this class set the command error bit (bit 5) in the event status register (IEEE 488.2, section 11.5.1). In this case:
•Either an IEEE 488.2 syntax error has been detected by the parser (a
•an unrecognized header was received. These include incorrect
Macro parameter error | |
| A command inside the macro definition had the wrong number or type of |
| parameters. |
Invalid inside macro definition | |
| The program message unit sequence, sent with a *DDT or a *DMC command, |
| is syntactically invalid (see IEEE 488.2, 10.7.6.3). |
Invalid outside macro definition | |
| A macro parameter placeholder ($<number) was encountered outside of a |
| macro definition. |
Macro error | |
| This error, as well as errors |
| defining a macro or executing a macro. This particular error message is |
| used if the device cannot detect a more specific error. |
Expression data not allowed | |
| A legal expression data was encountered, but was not allowed by the |
| device at this point in parsing. |
Invalid expression | |
| The expression data element was invalid (see IEEE 488.2, 7.7.7.2). For |
| example, unmatched parentheses or an illegal character. |
Error Messages | 49 |