Agilent Technologies E4400-90333 During the first power up after downloading new firmware into, 226

Page 28

-299 to -200: Execution Errors

ESG Family Signal Generators

 

Data corrupt or stale; License file is obsolete, missing

 

entries defaulted.

 

This error can only occur during the instrument’s first power up after

 

having downloaded new firmware. It indicates that the software license

 

file is missing entries for options supported by the current revision of

 

firmware. The missing entries have been added to the file, and their

 

license key values have been defaulted to zero. This error will occurs

 

during the first power up after downloading new firmware into the

 

instrument.

 

Data corrupt or stale; RAM copy of <filename>.

 

The non-volatile RAM copy of a file is either corrupt or is out of date with

 

the EEPROM master copy (if one exists). The system automatically

 

re-initializes the file from EEPROM (if appropriate) or from a default

 

algorithm. A potential cause is a failing backup battery.

-226

Lists not same length

 

Attempted to use LIST structure having individual LISTs of unequal

 

length.

-225

Out of memory

 

The device has insufficient memory to perform the requested operation.

-224

Illegal parameter value

 

Used where exact value, from a list of possibilities, was expected.

Illegal parameter value; Command requires at lease one data value.

A modulation type cannot be created without data.

Illegal parameter value; Total user file bits must be greater than 0.

An attempt was made to select a user file that contains 0 bits. Select another user file that contains at least 1 bit.

Illegal parameter value; Total user file bits must be greater than 0 and smaller than 500000.

The current hardware supports user file size between 1 and 500000 bits. Select a different file with the correct size.

26

Error Messages

Image 28
Contents Affix Label Here Part No. E4400-90333 Supersedes February Copyright 1999-2001 Agilent TechnologiesContents Introduction Error Message Format Error Message Types No Error To -400 Query Errors To -300 Device-Specific Errors Device has detected a failure during its self-test procedureNearest Agilent Technologies sales or service office Self-test for a particular power supply voltage has failed.Burst generator memory failed. Modulation data produced by 321Out of memory ARB communication failed Out of memory Could not copy current istate Out of memory Histogram display cannot function Out of memory Memory allocation error Out of memory Object Memory Area Lost. The meaning of this error is device-dependent Instrument is still functional320 315Non-volatile data saved by the *SAV? command has been lost Protected user data saved by the *PUD command has been lostAn error was detected in the device’s memory ValuesSystem error File Not Found To -200 Execution Errors When parsing a downloaded program is device-specific 285284 IllegalCommand header, or contained invalid header syntax Due to an error within the macro definition see Ieee 488.2Attempted. The definition of a math error is device-specific 276filename of was specified. This is not a legal filename An illegal memory subsystem name was used after the @File name error Illegal filename character File name not found SYSTEMFCDMA2KCHANFILE 254 Definition of what constitutes full media is device-specificCatalog. Afterwards, try again Try againSales or service office 252What constitutes missing media is device-specific 250Measurement accuracy is questionable Data corrupt or stale filename During the first power up after downloading new firmware into Algorithm. a potential cause is a failing backup batteryEeprom master copy if one exists. The system automatically 226223 Memory or related device-specific requirementsTo -200 Execution Errors Too much data User filter has too many symbols Data out of range Synthesizer Frequency out of bounds Data out of range value clipped to upper limit To -200 Execution Errors All digital modulation multicarriers must be the same format To -200 Execution Errors ESG Family Signal Generators Settings conflict Edge Bert requires Normal as Timeslot Type Settings conflict FM & PM not allowed Settings conflict GSM Bert requires Normal as Timeslot Type ESG Family Signal Generators Settings conflict I/Q & AM WB cannot be on at the same time ESG Family Signal Generators To -200 Execution Errors Used in RC1 Used in RC3 and 4 for channelTo -200 Execution Errors ESG Family Signal Generators For errors -221 through ErrorManual mode is on and therefore the instrument cannot sweep 220Have described the error that is stalling list/sweep 212Ignored 211Execution Error Cannot update FlexDG with Even Second Delay To -100 Command Errors Specified filename exceeds the maximum length Device cannot detect a more specific error Detect a more specific error150 148Header contains more than twelve characters see Ieee 488.2 110Command header error Syntax error 201 to 702 Device-Specific Errors Invalid file nameState file is not readable and the recall was aborted User has attempted to write to a read-only memory subsystemInternal error report to factory Synthesizer is unlocked. Service may be neededInstrument’s output is unleveled 513 1 GHz Oscillator unlocked Calibration failure Dcfm DC overrange Reverse Power Protection RPP Tripped DSP FW download failed Demodulator board DSP times out Demodulator communication failed Option 300 DSP for Bert capability returns an error Configuration Error Option reconfiguration failed Configuration error Installed board not supported Configuration error OPTION, Invalid inconsistent license key Demodulator board has an invalid revision of DSP boot code Option UN7 hardware has an invalid revision of Fpga codeFpga download failed Demodulator board filter must have at least one coefficient specified Modulation must have at least two states specifiedfile is either corrupt or is not a FIR file Burst shape file is corrupted, or is not in the proper format