Epson STYLUS NX100/NX105/SX100/SX105/TX100/TX101/TX102/TX103/TX105/TX106/TX109/ME 300 | Revision A |
Table 3-2. Check point for Fatal error according to each phenomenon
Occurrence timing
CR position
Detailed phenomenon
Defective
unit/part name
Check point
Remedy
•Power on
•Anywhere
1.Check if the Upper Paper Guide is correctly assembled. 1. Reassemble the Upper Paper Guide to the Main Frame correctly.
Upper Paper Guide
The Carriage Unit collides with the Upper | Upper Paper Guide |
Paper Guide Unit when power is turned | |
on. |
|
1. Check if the CR Scale does not come off or it properly | 1. Reassemble the CR Scale correctly. |
passes through the slit of the CR Encoder Board. | * If the problem is not solved, replace the Main |
| Board with a new one. |
When turning on the power, the Carriage |
|
|
|
|
|
|
|
|
|
|
| Slit of the CR Encoder Board |
|
|
|
| |||
Unit collides to the right side of the Main | CR Scale |
|
|
|
|
|
| ||
|
|
|
|
|
|
| |||
Frame. |
|
|
|
|
|
|
|
|
|
| 2. Check if the CR Scale is damaged or contaminated. | 2. Replace the CR Scale with a new one or clean it | |||||||
|
| ||||||||
|
|
|
|
|
|
|
|
| completely. |
|
|
|
|
|
|
|
|
| |
|
|
|
|
| CR Scale |
|
| ||
|
|
|
|
|
|
|
|
|
|
TROUBLESHOOTING | Error Indications and Fault Occurrence Causes | 33 |