Epson STYLUS NX100/NX105/SX100/SX105/TX100/TX101/TX102/TX103/TX105/TX106/TX109/ME 300 | Revision A |
4.5.7 Ink System
Parts/Components need to be removed in advance:
Scanner Stand/Cover Wire (p60), Scanner Unit (p62), Middle Housing (p63) Panel Unit (p64), CR Motor/ Driven Pulley (p75)
Removal procedure
CAUTION Be careful not to contaminate the surroundings with ink.
Do not bend the Spring Cleaner Lever and the Cleaner Case Spring.
Do not touch the Sealing Rubber, the Blade Wiper or the Felt
Wiper with bare hands or damage them.
Cap Assy
1.Remove the Cleaner Lever Spring.
2.Remove the Cleaner Case Spring.
Cap Assy |
Lever Cleaner
3.Insert a flathead precision screwdriver between the Lower Housing and the Pump Assy and push it in the direction of the arrow to release the hook.
Pump Assy
Hook |
Figure 4-50. Removing the Cap Assy (2)
4.Move the Pump Assy to the ASF slightly, and remove the protrusion B of the Cap Assy.
5.Remove the two protrusion Cs of the Pump Assy from the Lower Housing.
Pump Assy
Protrusion A
Cleaner Lever Spring
Cleaner Case Spring
Hole |
Cap Assy |
Figure 4-49. Removing the Cap Assy (1)
Protrusion B
Protrusion C
Figure 4-51. Removing the Cap Assy (3)
DISASSEMBLY/ASSEMBLY | Disassembling the Printer Mechanism | 77 |