Epson STYLUS NX100/NX105/SX100/SX105/TX100/TX101/TX102/TX103/TX105/TX106/TX109/ME 300 | Revision A |
3.Secure point C of the tube to the Pump Housing as shown below.
Pump Housing
Point C |
Ink Tube |
Figure 4-65. Assembling the Pump Assy (2)
4.Install the Roller Pump to the Bracket Pump. (See Fig.4-62.)
5.Set the tube inside the Bracket Pump, and install the Bracket Pump to the Pump Housing.
6.Rotate the Bracket Pump shaft and make sure that the Roller Pump shalt moves to both ends in the Groove.
Bracket Pump | Roller Pump shaft |
|
Groove |
Ink Tube | Bracket Pump shaft |
|
Figure 4-66. Assembling the Pump Assy (3)
7.Make sure that point C is placed in the correct position. (See Fig.4-65.)
8.Install the Gear Pump. (See Fig.4-62.)
9.Install the Gear Pump Idle. (See Fig.4-62.)
4.5.8 PF Motor
Parts/Components need to be removed in advance:
Scanner Stand/ Cover Wire (p60), Scanner Unit (p62), Middle Housing (p63) Panel Unit (p64), Hopper (p72), Main Board (p65)
Removal procedure
1.Pull out the PF Motor cable and the Ferrite Core from the hole of the Lower Housing to release them.
Rib | Ferrite Core |
|
PF Motor cable | PF Motor |
|
Figure 4-67. Removing the PF Motor (1)
2.Remove the Grounding Spring from the hook of the Main Frame and the Bracket.
| Grounding Spring |
Hook | Tip of the Grounding |
Spring |
PF Roller | Bracket | Hole |
|
|
Figure 4-68. Removing the PF Motor (2)