6.Pull out the Waste Ink Tube through the rear of the Cap Assy, and remove the Cap Assy.
Cap Assy |
Point A
Ink Tube |
Figure 4-52. Removing the Cap Assy (4)
Pump Assy
1.Pull out the Waste Ink Tube together with the Holder Tube through the Waste Ink Cover.
2.Release the Waste Ink Tube from the hook of the ASF Unit.
Hook | Ink Tube |
3.Release the two hooks, and remove the Pump Assy from the Lower Housing.
Pump Assy | Pump Assy | |
Hook | ||
|
Figure 4-54. Removing the Pump Assy (2)
When installing the Cleaner Lever Spring, insert the longer end of the spring into the Lower Housing, and secure it to the protrusion A of the Cleaner Lever attached through the hole of the Lower Housing. (See Fig.4-49.)
ASF Unit |
Point D
Holder Tube
Duct Tube End
Figure 4-53. Removing the Pump Assy (1)
DISASSEMBLY/ASSEMBLY | Disassembling the Printer Mechanism | 78 |