Epson STYLUS NX100/NX105/SX100/SX105/TX100/TX101/TX102/TX103/TX105/TX106/TX109/ME 300 | Revision A |
2.Remove the four screws that secure the Main Board.
3.Remove the Main Board and the Shield Plate with the PE Sensor Lever to the ASF side as shown below.
4.4.3 Power Supply Unit
Parts/Components need to be removed in advance: |
Scanner Stand/Cover Wire (p60), Scanner Unit (p62), Middle Housing (p63) |
PE Sensor |
PE Sensor Lever
Rib |
Shield Plate | Main board |
SCREW SEMS M2.6x3.5 PAN HEAD+ (7.5±0.5kgfcm)
Panel Unit (p64) | |
Removal procedure | |
1. | Disconnect the connector of the Power Supply Unit Cable (J3) from the Main |
| Unit and release the Power Supply Unit cable from the ribs of the Lower |
2. | Housing. |
Remove the screw that secures the Power Supply Unit. | |
3. | Remove the Power Supply Unit from the Lower Housing. |
Figure 4-21. Removing the Main Board (2)
When installing the Main Board, keep the PE Sensor Lever away (as shown in Fig.4-21) to avoid getting broken.
Before tightening the screws, make sure to insert the Main Board to the rib of the Main Frame, and align the threaded hole of the Main Frame with the hole of the Main Board. (See Fig.4-21.)
Tighten the screws in the order indicated in Fig.4-21.
For the Shield Plate, hook its upper part to the Main Frame and secure them as shown below.
Shield Plate
Main Frame
Figure 4-22. Installing the Main board
ADJUSTMENT Whenever the Main Board Unit is removed/replaced, the required | |
REQUIRED | adjustments must be carried out. |
| • Chapter 5 “ ADJUSTMENT” (p.100) |
J3 |
Lower housing
Power Supply UnitPower Supply Unit cable
SCREW M3x8
Figure 4-23. Removing the Power Supply Unit
DISASSEMBLY/ASSEMBLY | Removing the Circuit Boards | 66 |