Epson STYLUS NX100/NX105/SX100/SX105/TX100/TX101/TX102/TX103/TX105/TX106/TX109/ME 300 | Revision A |
Buttons
1.Remove the Button Power and the Button OP from the Panel Cover.
2.Remove the LED Lens from the Panel Cover.
Button OP | LED Lens | Button Power |
Panel Cover | Dowel |
Figure 4-19. Removing the Buttons
When installing the Panel Board, align the positioning hole of the Panel Board with the dowels of the Panel Cover. (See Fig.4-18)
When installing the Panel Unit, align the positioning holes of the Middle Housing with the dowels of the Panel Cover, then secure them with four hooks. (See Fig.4-16, Fig.4-19.)
4.4.2 Main Board
Parts/Components need to be removed in advance:
Scanner Stand/Cover Wire (p60), Scanner Unit (p62), Middle Housing (p63) Panel Unit (p64), Hopper (p72)
Removal procedure
1. Remove all the cables and FFCs connected to the Main Board.
CN No | Cable | Cable Color | Connector | Pins | |
Color | |||||
|
|
|
| ||
|
|
|
|
| |
J2 | Panel FFC | Black | 10 | ||
|
|
|
|
| |
J3 | Power Supply Unit cable | Gray | Brown | 3 | |
|
|
|
|
| |
J4 | Scanner FFC | Black | 12 | ||
|
|
|
|
| |
J5 | Scanner Motor Cable | Black,Brown, | White | 4 | |
|
| Orenge,Yellow |
|
| |
|
|
|
|
| |
J6 | PF Motor Cable | Red, | White | 2 | |
|
| Black |
|
| |
|
|
|
|
| |
J7 | CR Motor Cable | Gray, | Brown | 2 | |
|
| Black |
|
| |
|
|
|
|
| |
J8 | Head FFC | Black | 21 | ||
|
|
|
|
| |
J9 | FFC | Black | 17 | ||
|
|
|
|
|
J9 | J8 | J5 | J4 | J2 |
Main Board |
J6 | J3 | J7 |
Figure 4-20. Removing the Main Board (1)
DISASSEMBLY/ASSEMBLY | Removing the Circuit Boards | 65 |