Epson STYLUS NX100/NX105/SX100/SX105/TX100/TX101/TX102/TX103/TX105/TX106/TX109/ME 300 | Revision A |
Table 3-2. Check point for Fatal error according to each phenomenon
Occurrence timing
CR position
Detailed phenomenon
Defective
unit/part name
Check point
Remedy
•Power on
•Anywhere
When turning on the power, the Carriage cannot get out of home position.
| 3. | Check if the Spring Cleaner Lever comes off from the | 3. | Reassemble the Cleaner Lever Spring correctly. | ||||
|
| Lever Cleaner. |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Lever Cleaner |
|
|
|
Ink System |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| Cleaner Lever |
|
|
|
|
|
|
|
| Spring |
|
|
| ||
|
|
|
|
|
|
|
|
|
| 4. | Check the routing of the Waste Ink Tube. | 4. | Route the Waste Ink Tube correctly. | ||||
|
|
|
|
|
|
|
| (Refer to Chapter 4 “Ink System” (p.77)) |
|
|
|
|
|
|
|
|
|
| 5. | Check if the Cap Assy is damaged. | 5. | Replace the Cap Assy with a new one. | ||||
|
|
|
|
|
|
|
| |
Main Frame | 1. Check if the Main Frame is deformed. | 1. | Replace the Main Frame with a new one. | |||||
|
|
|
|
|
|
|
|
|
Table
Occurrence
timing
CR position
Detailed phenomenon
Defective
unit/part name
Check point
Remedy
•Operation
•–
An error is indicated on the LED and STM or LCD.
Waste Ink Pads
1.Change the Waste Ink Pads and initialize the Waste Ink Pad Counter. (Refer to Chapter 5 “ADJUSTMENT” (p.100))
TROUBLESHOOTING | Error Indications and Fault Occurrence Causes | 36 |