Schneider Electric 66074, 66846 Tables of alarms and events, UPS Alarm table, STS Alarm table

Page 73

Network

Management Card

User Manual

8 Appendices

8.1Tables of alarms and events

8.1.1

UPS Alarm table

 

 

 

English

French

Battery Fault

Défaut batterie

Output On Battery

Sortie alimentée par batterie

Low Battery

Fin d’autonomie

UPS Over Temperature

Défaut température

Output not protected

Sortie non protégée

UPS Overload

Surcharge onduleur

Output On Bypass

Sortie sur Bypass

Charger Fault, Not Charging Battery

Défaut chargeur

Utility failure

Perte secteur

No Battery

Pas de batterie

Replace Battery

Batterie à remplacer

Unavailable Battery

Batterie indisponible

Boost Activated on UPS

Onduleur en mode Boost

Buck Activated on UPS

Onduleur en mode Buck

<Sensor name>: Temperature is

<Sensor name>: La température est au

above high threshold xx °C

dessus du seuil haut xx °C

"<Sensor name>: Humidity is above

<Sensor name>: L'humidité est au dessus du

high threshold xx %",

seuil haut xx %",

<Sensor name>: Temperature is below

<Sensor name>: La température est en

low threshold xx °C

dessous du seuil bas xx °C

<Sensor name>: Humidity is below low

<Sensor name>: L'humidité est en dessous du

threshold xx %

seuil bas xx %

<Sensor name>: <Input #1 label>

<Sensor name>: <Input #1 label> <when

<when closed label>

closed label>

<Sensor name>: <Input #1 label>

<Sensor name>: <Input #1 label> <when open

<when open label>

label>

<Sensor name>: <Input #2 label>

<Sensor name>: <Input #2 label> <when

<when closed label>

closed label>

<Sensor name>: <Input #2 label>

<Sensor name>: <Input #2 label> <when open

<when open label>

label>

8.1.2

STS Alarm table

 

 

 

English

French

Source 1 Static Switch fault

Défaut Contacteur Statique source 1

KM1 fault

Défaut Contacteur source 1 (KM1)

Source 2 Static Switch fault

Défaut Contacteur Statique source 2

KM2 fault

Défaut Contacteur source 2 (KM2)

Source 1 voltage fault

Défaut tension source 1

Source 1 frequency fault

Défaut frequence source 1 hors tolerances

Source 2 voltage fault

Défaut tension source 2

Source 2 frequency fault

Défaut frequence source 2 hors tolerances

Output not powered

Charge non alimentée

Transfer forbiden

Transfert interdit

Network Management Card – User Manual

34003676EN/HA

Page 73/81

Image 73
Contents Network Management Card NMC Transverse Environment Sensor Network Management Card Configuration VIA Telnet Configuration VIA SSH ConfigurationMAINTENANCE72 Software Upgrade Appendices Tables of Alarms and EventsGlossary Introduction Connecting the UPS / STS to the NetworkNetwork Management Card Protecting the computers / servers MGE supervisor Enterprise Power ManagerMonitoring the UPSs over the network Network Shutdown module only available for UPS, not for STSSetting up the protection, for UPS only How to connect UPS / networkConnection Presentation of the Network Management Cards NMCDirect sending of E-mail Presentation of the Environment Sensor solutionSending text messages SMS Technical data 10/81 Basic configuration InstallationEnvironment Sensor Optimising the performance of your browser Supervision / Administration via a Web browserUPS properties UPS / STSUPS zone general information on the UPS UPS status zone essential informationBattery status zone STS zone general information on the STS STS propertiesSTS status zone essential information Sources status zone AboutOn-line help 18/81 Normal input measurements UPS 3-Phase displayBy Pass measurements Battery measurementsSTS 3-Phase display Source 2 input measurement UPS Control23/81 UPS weekly schedule programming Important note Shutdown parametersViewing the alarms UPS Measurements LogsSTS Measurements 29/81 STS Event log UPS Event log31/81 System log 33/81 UPS Email Notification NotificationNotified events Recipient List Mail message configuration see nextSTS Email Notification Other settingsUPS Email Message Settings Email Message SettingsSender SubjectSTS Email Message Settings Email Example User Name and password by default are Mgeups ConfigurationNetwork Settings 42/81 System 44/81 UPS Notified Applications 46/81 Central Shutdown Configuration STS Notified Applications 49/81 Access control 51/81 Access is disabled and the card is accessible in SSH Time Status Configuration Log CharacteristicsEnvironment Environment status 56/81 UPS Environment Settings UPS Environment SettingsHumidity STS Environment Settings4 Log Shutdown criteria managed by the Management Card Set-up of the shutdown parametersShutdown when backup time is less than Specific set-up for long autonomy installation 30 mnShutdown duration Different server and UPS shutdown sequences 63/81 4 Off/On command Configuration in local mode Configuring a set of cards with MupgradeMgeups Choice 1 Snmp agent configuration menuChoice 2 UPS / STS parameters Choice 3 Access controlChoice 5 Reset the card Choice 4 Restore default configurationConfiguration via SSH Configuration via TelnetPuTTY SSH Client Program 70/81 71/81 Card firmware upgrade using Mupgrade Windows Software upgradeCard software upgrade via Tftp Unix and Windows UPS Alarm table Tables of alarms and eventsSTS Alarm table English FrenchUPS event table UPS STS event table 77/81 System alarm table Glossary Telnet Subnet maskTrap Snmp