APC 1000, 1400, 650, 420 user manual Specifications, Extended storage

Page 19

11.2 Extended storage

During extended storage in environments where the ambient temperature is –15 to +30 °C (+5 to +86 °F), charge the UPS’s battery every 6 months

During extended storage in environments where the ambient temperature is +30 to +45 °C (+86 to +113 °F), charge the UPS’s battery every 3 months.

12. Specifications

 

420 VA

650 VA

 

1000 VA

1400 VA

 

 

 

 

 

Acceptable input voltage

 

0 - 160 VAC

 

 

 

 

 

 

Input voltage (on-line operation)

 

92-150

VAC

 

 

 

 

 

 

Output voltage

 

103-132

VAC

 

 

 

 

 

Nominal input frequency

 

50 or 60 Hz, autosensing

 

 

 

 

 

Input Protection

 

Resettable circuit breaker

 

 

 

 

 

Frequency limits (on-line operation)

 

50 or 60 Hz, ±5%

 

 

 

 

 

Transfer time

 

2 ms typical, 4 ms maximum

 

 

 

 

 

 

Maximum load

420 VA 280 W

650 VA 400 W

 

1000 VA 670 W

1400 VA 950 W

 

 

 

 

 

On-battery output voltage

 

115 VAC

 

 

 

On-battery frequency

50 or 60 Hz, ±0.1 Hz; unless synchronized to utility during brownout.

 

 

 

On-battery waveshape

Stepped sine-wave

 

Trapezoid

 

 

 

Protection

Overcurrent and short-circuit protected, latching shutdown on overload.

 

 

 

 

 

 

Surge energy rating (one time,

320 J

 

480 J

10/1000 µs waveform)

 

 

 

 

 

 

 

 

 

 

 

 

Surge current capability (one time,

 

6500 A maximum

 

8/20 µs waveform)

 

 

 

 

 

 

 

 

 

 

 

Surge response time

 

0 ns (instantaneous) normal mode;

 

 

<5 ns common mode

 

 

 

 

 

 

 

 

 

 

Surge voltage let-through (percentage

0.7%

 

0.3%

of applied ANSI C62.41 Cat. A ±6

 

kV test waveform)

 

 

 

 

 

 

 

 

Noise Filter

Normal and common mode EMI/RFI suppression,

 

100 kHz to 10 MHz

 

 

 

 

 

 

Battery type

Spill proof, maintenance free, user replaceable, sealed lead-acid

 

 

Typical battery life

3 to 6 years, depending on number of discharge cycles and ambient

 

temperature

 

 

 

 

 

 

 

 

Typical recharge time

 

2 to 5 hours from total discharge

 

 

 

 

 

 

 

English

15

Image 19
Contents Smart-UPS v/s Page Contents/Sections/Indice Part Number Revised 11/94 Thank you IntroductionPlease save the packaging materials Theory of Operation Radio Frequency InterferencePower Management Software SafetyFeatures Intelligent Battery ManagementFront panel Presentation650 VA 1400 VA InstallationRear Panel InspectionConnect Telephone/Network Surge Suppression Optional PlacementProtection Strategies Connect Computer Interface OptionalConnect the Loads Charge the batteryCheck the Site Wiring Fault Indicator Connect to UtilitySelf-test Switch On Switch OffShutdown Mode OperationOptions AlarmsWall Mount Bracket TroubleshootingService Replacement Batteries Replacing the BatteryBattery Replacement Procedure 420 and 650 VA models Storage Battery Replacement Procedure 1000 and 1400 VA modelsStorage conditions Extended storage SpecificationsSafety and approvals Computer Interface Port 1000 VA 1400 VA Load 650 VA How to Determine On-battery Run TimeVeuillez conserver l’emballage de votre onduleur MerciPrincipe de fonctionnement Interférences radioélectriquesLogiciel de gestion électrique Consignes de sécuritéFonctions Gestion intelligente de la batteriePanneau avant Présentation420 et 650 VA 1000 et 1400 VA Panneau arrièreStratégies de protection Choix d’un emplacementBranchement des équipements Branchement de l’interface pour ordinateur en optionBranchement au secteur Chargement de la batterieVérification du voyant de défaut de câblage de site FonctionnementMise sous tension et arrêt Test automatique de fonctionnement Mode d’arrêt completAlarmes En cas de problème Problème Cause possible SolutionRéparations Français Page Français Stockage longue durée StockageCaractéristiques techniques Conditions de stockageAppliquée par Ansi C62.41 cat. a ±6 Filtrage dinterférences Page Comment déterminer l’autonomie de la batterie Remarques ¡Por favor guarde los materiales de embalaje Introducción¡Gracias ¡ImportanteTeoría de Operación Interferencia con Radio FrecuenciaSoftware de Administración de Energía Administración Inteligente de la BateríaCaracterísticas ¡PRECAUCION Seguridad420 y 650 VA PresentaciónPanel delantero Panel PosteriorInspección Instalación1000 y 1400 VA Estrategias de Protección ColocaciónConexión de la Interfase del Computador Opcional Carga de la batería Conexión a la red eléctricaConexión de las cargas Comprobación del Indicador de Fallos de Cableado OperaciónEncender Apagar En-batería AlarmasPrueba automática Modalidad apagadaOpciones Problema Causa posible Solución Detección y solución de problemasServicio Baterías de reemplazo Procedimiento de reemplazo de baterías modelos 420 y 650 VA Page Almacenaje prolongado AlmacenamientoEspecificaciones Condiciones de almacenajePorcentaje de Ansi C62.41 Cat a Serie Interfase Puerto del Computador 13. Cómo determinar el tiempo de operación en-batería Limited Warranty Garantía Limitada