APC 420, 1400, 650, 1000 user manual Radio Frequency Interference, Theory of Operation

Page 6

1.2 Radio Frequency Interference

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communi- cations. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes interference to radio or television reception, which can be determined by turn- ing the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

nreorient the receiving antenna

nincrease the separation between the equipment and the receiver

nconnect the equipment to an outlet on a circuit different from that to which the receiver is connected

nconsult the dealer or an experienced radio/TV technician for help.

Shielded communications interface cables must be used with this product.

War ning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

1.3 Theory of Operation

This high-performance, line-interactive, uninterruptible power source (UPS) provides clean, reli- able, AC power to computer systems — protecting them from power blackouts, brownouts, swells, sags, surges, and interference.

Normally, the UPS operates “on-line,” supplying power from the utility input to the load (work- station, server, or other device). The converter circuitry is used to maintain an optimal float charge level on the battery.

When the utility fails, the disconnect switch opens and the converter supplies AC power to the load. The loads operate normally until shut down or until the battery is exhausted. The UPS auto- matically transfers the load back to utility power and recharges the batteries when the line voltage returns to normal.

The UPS also provides surge protection and EMI/RFI filtering, as well as SmartBoost™ and SmartTrim™ (automatic voltage regulation), which corrects high and low input voltage without drawing power from the battery.

2

Image 6
Contents Smart-UPS v/s Page Contents/Sections/Indice Part Number Revised 11/94 Introduction Thank youPlease save the packaging materials Radio Frequency Interference Theory of OperationIntelligent Battery Management SafetyFeatures Power Management SoftwarePresentation Front panelInspection InstallationRear Panel 650 VA 1400 VAConnect Computer Interface Optional PlacementProtection Strategies Connect Telephone/Network Surge Suppression OptionalConnect to Utility Charge the batteryCheck the Site Wiring Fault Indicator Connect the LoadsOperation Switch On Switch OffShutdown Mode Self-testAlarms OptionsTroubleshooting Wall Mount BracketService Replacing the Battery Replacement BatteriesBattery Replacement Procedure 420 and 650 VA models Battery Replacement Procedure 1000 and 1400 VA models StorageStorage conditions Specifications Extended storageSafety and approvals Computer Interface Port How to Determine On-battery Run Time 1000 VA 1400 VA Load 650 VAMerci Veuillez conserver l’emballage de votre onduleurInterférences radioélectriques Principe de fonctionnementGestion intelligente de la batterie Consignes de sécuritéFonctions Logiciel de gestion électriquePrésentation Panneau avantPanneau arrière 420 et 650 VA 1000 et 1400 VAChoix d’un emplacement Stratégies de protectionChargement de la batterie Branchement de l’interface pour ordinateur en optionBranchement au secteur Branchement des équipementsFonctionnement Vérification du voyant de défaut de câblage de siteMise sous tension et arrêt Mode d’arrêt complet Test automatique de fonctionnementAlarmes Problème Cause possible Solution En cas de problèmeRéparations Français Page Français Conditions de stockage StockageCaractéristiques techniques Stockage longue duréeAppliquée par Ansi C62.41 cat. a ±6 Filtrage dinterférences Page Comment déterminer l’autonomie de la batterie Remarques ¡Importante Introducción¡Gracias ¡Por favor guarde los materiales de embalajeInterferencia con Radio Frecuencia Teoría de OperaciónAdministración Inteligente de la Batería Software de Administración de EnergíaCaracterísticas Seguridad ¡PRECAUCIONPanel Posterior PresentaciónPanel delantero 420 y 650 VAInstalación Inspección1000 y 1400 VA Colocación Estrategias de ProtecciónConexión de la Interfase del Computador Opcional Conexión a la red eléctrica Carga de la bateríaConexión de las cargas Operación Comprobación del Indicador de Fallos de CableadoEncender Apagar Modalidad apagada AlarmasPrueba automática En-bateríaOpciones Detección y solución de problemas Problema Causa posible SoluciónServicio Baterías de reemplazo Procedimiento de reemplazo de baterías modelos 420 y 650 VA Page Condiciones de almacenaje AlmacenamientoEspecificaciones Almacenaje prolongadoPorcentaje de Ansi C62.41 Cat a Serie Interfase Puerto del Computador 13. Cómo determinar el tiempo de operación en-batería Limited Warranty Garantía Limitada