TDK 1500W, 750W technical manual Vout

Page 18

2.6 PROGRAMMING AND READBACK (RS232/485, Optional IEEE Int

1.

Vout programming accuracy

 

 

0.05% + 0.05% of rated output voltage.

 

 

 

 

 

 

 

 

 

 

 

 

2.

Iout programming accuracy (*13)

 

0.1% of actual output current + 0.1% of rated output current (for Iout >0.4% of rated Iout to 100% of rated Iout).

 

 

 

 

 

 

0.1% of actual output current +0.4% of rated output current (for Iout <0.4% of rated Iout to 0.4% of rated Iout).

 

3.

Vout programming resolution.

 

 

0.012% of full scale.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Iout programming resolution

 

 

0.012% of full scale.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.

Vout readback accuracy

 

 

0.1% + 0.1% of rated output voltage

 

 

 

 

 

 

 

 

 

 

 

 

6.

Iout readback accuracy (*13)

 

 

0.1% + 0.3% of rated output current

 

 

 

 

 

 

 

 

 

 

 

 

7.

Vout readback resolution

 

 

0.012% of full scale

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.

Iout readback resolution

 

 

0.012% of full scale

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.7 PROTECTIVE FUNCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

6

8

 

12.5

20

30

40

50

60

 

80

 

100

150

 

300

600

1.

Foldback protection

 

Output shut-down when power supply changes from CV to CC. User presetable.

 

 

 

 

 

 

 

2.

Over-voltage protection

 

Inverter shut-down; manual reset by AC input recycle, OUT button.

 

 

 

 

 

 

 

 

 

 

3.

Over-voltage trip point

 

V

 

0.5-7.5

0.5-10

 

1-15

1-24

2-35

2-44.1

5-57

5-66

 

5-88

 

5-110

5-165

 

5-330

5-660

4.

Output under voltage limit

 

Preset by front panel or communication port. Prevents adjusting Vout below limit. Raises the PS_OK signal in case

 

 

 

 

 

output

voltage is below limit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.

Over temperature protection

 

User selectable, latched or non latched.

 

 

 

 

 

 

 

 

 

 

 

 

 

2.8 FRONT PANEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Control functions

 

 

Vout/Iout manual adjust by separate encoders. (Coarse and fine adjustment)

 

 

 

 

 

 

 

 

 

 

 

OVP/UVL manual adjust by Volt. Adjust encoder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Address selection by Voltage adjust encoder. No of addresses: 31

 

 

 

 

 

 

 

 

 

 

 

 

 

Go to local control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output on/off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC on/off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front panel lock

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Foldback control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial or IEEE display at power-up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Baud rate selection: 1200, 2400, 4800, 9600 and 19200

 

 

 

 

 

 

 

 

 

 

 

 

 

Re-start modes (Auto Restart, Safe Start)

 

 

 

 

 

 

 

 

 

 

 

2.

Display

 

 

Vout:

4 digits, accuracy: 0.5% of rated voltage + 1 count

 

 

 

 

 

 

 

 

 

 

 

 

 

Iout:

4 digits, accuracy: 0.5% of rated current + 1 count

 

 

 

 

 

 

 

 

 

3. Indications

 

 

VOLTAGE, CURRENT, ALARM FINE, PREVIEW, FOLDBACK, LOCAL, OUTPUT ON.

 

 

 

 

 

2.9 ENVIRONMENTAL CONDITIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Operating temperature

 

C

 

0~50 C, 100% load.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Storage temperature

 

C

 

-20 to + 70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Operating humidity

 

%

 

30~90% RH (no condensation).

 

 

 

 

 

 

 

 

 

 

 

 

4.

Storage humidity

 

%

 

10~95% RH (no condensation).

 

 

 

 

 

 

 

 

 

 

 

 

5.

Altitude

 

 

Maximum 3000m, Derate output current by 2%/100m above 2000m. Alternatively, derate maximum ambient

 

 

 

 

 

 

temperature by 1 degC/100m above 2000m.

 

 

 

 

 

 

 

 

 

 

 

2.10 MECHANICAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Cooling

 

 

Forced air cooled by internal fans.

 

 

 

 

 

 

 

 

 

 

 

 

2.

Weight

 

Kg

 

Less than 4.5Kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Dimensions (W x H x D)

 

mm

 

W: 214.0 H: 43.6 (57.0 Benchtop Version). D: 437.5 (Refer to Outline drawing).

 

 

 

 

 

 

 

4.

Vibration

 

 

MIL-810E, method 514.5 test condition l-3.3

 

 

 

 

 

 

 

 

 

 

 

5.

Shock

 

 

Less than 20G, half sine, 11mS. Units unpacked

 

 

 

 

 

 

 

 

 

 

 

2.11 SAFETY/EMC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Applicable standards

Safety

 

UL 60950-1 listed, EN 60950-1 Vout <= 40V: Output is SELV, IEEE/Isolated Analog are SELV.

 

 

 

 

 

 

 

 

 

 

 

 

 

60 < Vout < 400V: Output is hazardous, IEEE/Isolated analog are SELV

 

 

 

 

 

 

 

 

 

 

 

400 < Vout < 600V: Output is hazardous, IEEE/Isolated, Analog are not SELV

 

 

 

EMC

 

EN55024

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Withstand voltage

 

 

Vout < 60V models: Input-Outputs (SELV): 3.0KVrms 1 min, Input-Ground: 2.0KVrms 1 min.

 

 

 

 

 

 

 

 

 

60 <= Vout < 600V models: Input-Haz, output: 2.5KVrms 1 min, Input-SELV: 3KVrms 1 min, 1900VDC 1 min.

 

 

 

 

 

 

Hazardous Output - SELV: 1.9KVrms 1 min, Hazardous Output-Ground: 1.9KVrms 1 min.

 

 

 

 

 

 

 

 

 

Input-Ground: 2KVrms 1min

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Insulation resistance

 

 

More than 100Mohm at 25°C, 70%RH

 

 

 

 

 

 

 

 

 

 

 

 

4. Conducted emission

 

 

EN55022B, FCC part 15-B, VCCI-B

 

 

 

 

 

 

 

 

 

 

 

 

5. Radiated emission

 

 

EN55022A, FCC part 15-A, VCCI-A

 

 

 

 

 

 

 

 

 

 

 

 

10

83-507-013 Rev. D

Image 18
Contents Genesystm 750W/1500W Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and Connectors ………...……… Remote Analog PROGRAMMING……………………………………………… Isolated Analog Programming OPTION………………………………… Disclaimer Limitation of WarrantyWarranty Service Trademark InformationSafety Instructions Environmental Conditions SICHERHEITS-INSTALLATIONS Anweisungen Sicherheits-und Warnsymbole Anderungen and BauteileersatzUmweltbedingungen Introduction Features and optionsGeneral Information General DescriptionAnalog voltage programming and monitoring Multiple output power systemControl via the serial communication port Parallel operationAccessories Specifications ChapterVout Supplemental Characteristics Genesystm 750W & 1500W Power Supplies Outline Drawings Preparation for USE InstallationGeneral Initial InspectionsAC Source Requirements AC Input Power ConnectionLOCATON, Mounting and Cooling Rack Mount Slides optionalAC Input Wire Connection, 1500W models AC Input Connector, 1500W modelsAC Input Connector, 750W models AC Input CordTURN-ON Checkout Procedure GeneralPrior to Operation OVP Check Constant Voltage CheckConstant Current Check UVL CheckConnecting the Load Wire termination AWGNoise and Impedance Effects Inductive loadsMaking the load connections 6V to 60V Models Wire terminal lug 2 places 80V to 600V ModelsLoad wires connection to the output connector Connecting single loads, local sensing default Connecting single loads, remote sensingConnecting multiple loads, radial distribution method Multiple load connection with distribution terminals Grounding outputsLocal and Remote Sensing Sense wiringOutput Terminal Grounding Local sensing10.4 J2 sense connector technical information Remote sensingFront and Rear Panel Controls and Connectors Front Panel Controls and IndicatorsAuxiliary Function Rear Panel Connections and Controls Rear panel connections and controlsRear Panel SW1 Setup Switch Resetting the SW1 switch 1 SW1 position functionRear Panel J1 Programming and Monitorng Connector Making J1 connectionsIfcom SignalEnain LocalConstant Voltage Mode Constant Current ModeLocal Operation Over Voltage Protection OVP Setting the OVP levelResetting the OVP circuit Automatic CrossoverFoldback Protection Output SHUT-OFF SO Control VIA Rear Panel J1 ConnectorUnder Voltage Limit UVL Output ON/OFF ControlENABLE/DISABLE Control VIA Rear Panel J1 Connector CV/CC SignalPsok Signal Auto-restart mode Over Temperature Protecton OTPLast Setting Memory Safe-start modeSeries Operation Series connection for increased output voltageSeries connection for positive and negative output voltage Series connection for positive/negative output voltagesParallel Operation Master and Slave units default operation Advanced parallel configurationSetting the units as Master or Slave Connection to the loadTo release units from Slave mode Current display accuracyAST OFF *OUT OFF Unlocked front panel DAISY-CHAIN ConnectionFront Panel Locking Locked front panelRemote Analog Programming LOCAL/REMOTE Analog IndicationDown Remote voltage programming connectionResisitive Programming of Output Voltage and Current Limit Remote resistive programmingRemote Monitoring of Output Voltage and Current RS232 & RS485 Remote Control ConfigurationRear Panel RS232/RS485 Connector 6 RS232/RS485 port in Local modeFront panel in Remote mode MD Mode SRQ MD Mode Option Factory Installed MD Mode DescriptionMD Mode enable Serial communication mode MD Mode SRQ RetransmissionConnecting Power Supplies to RS232 or RS485 BUS Single power supplyCommunication Interface Protocol Error Messages Command SET DescriptionInitialization Control Commands ID Control CommandsOutput Control Commands FILTER? DVC?Filter OUT?Global Output Commands Disable SRQ retransmission MD Mode Option Required Single Byte CommandsEnable MD Mode MD Mode Option Required Enable SRQ retransmission MD Mode Option RequiredTest if MD Mode is Installed Addressed commands with response Read registersPrint Power On Time Addressed commands without response Acknowledge SRQ1010 None Disable retransmission of SRQs by GEN750W models GEN1500W models Current programming range STATUS, Error and SRQ Registers 10.6 Status Control CommandsConditional Registers Status RegistersService Request Enable and Event Registers BITFault Enable Register Fault Event RegisterStatus Enable Register Status Event RegisterPower supply set-up Serial Communication Test SET-UPCommunication Test 1 0-5V/0-10V Option PN IS510 SpecificationsIsolated Analog Programming Option PPM/CIsolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance Fuse Rating OUP