TDK 1500W, 750W Dvc?, Filter?, Out?, Fld?, Fbd ?, Fbdrst, Ovp?, Ovm, Uvl?, Ast?, Sav, Rcl

Page 64

#

Command

 

Description

 

 

Display Voltage and Current data. Data will be returned as a string of ASCII

 

 

characters. A comma will separate the different fields. The fields, in order, are:

7

DVC?

Measured Voltage, Programmed Voltage, Measured Current, Programmed Cur-

 

 

rent, Over Voltage Set Point and Under Voltage Set Point.

 

 

Example: 5.9999,6.0000,010.02,010.00,7.500,0.000

8

FILTER

Set the low pass filter frequency of the A to D Converter for Voltage and Current

nn

Measurement where nn = 18, 23 or 46.

 

9

FILTER?

Returns the A to D Converter filter frequency: 18,23 or 46 Hz.

 

 

Turns the output to ON or OFF. Recover from Safe-Start, OVP or FLD fault.

10

OUT n

OUT 1 (or OUT ON)-Turn On.

 

 

OUT 0 (or OUT OFF)-Turn Off

11

OUT?

Returns the output On/Off status string.

 

 

ON - output On. OFF - output Off.

12

FLD n

Sets the Foldback protection to ON or OFF.

 

 

FLD 1 (or FOLD ON) - Arms the Foldback protection

 

 

FLD 0 (or FOLD OFF) - Cancels the Foldback protection.

 

 

When the Foldback protection has been activated, OUT 1 command will release

 

 

the protection and re-arm it, while FLD 0 will cancel the protection.

13

FLD?

Returns the Foldback protection status string:

“ON” - Foldback is armed. “OFF” - Foldback is cancelled.

 

 

14

FBD nn

Add (nn x 0.1) seconds to the Fold Back Delay. This delay is in addition to the

standard delay. The range of nn is 0 to 255. The value is stored in eprom at AC

 

 

power down and recovered at AC power up.

15

FBD ?

Supply returns the value of the added Fold Back Delay.

16

FBDRST

Reset the added Fold Back Delay to zero.

 

 

Sets the OVP level. The OVP setting range is given in Table 7-7. The number of

 

 

characters after OVP is up to 12. The minimum setting level is approximately

17

OVP n

105% of the Output Voltage setting, or the value in Table 7-7, whichever is

higher. The maximum OVP setting level is shown in Table 5-1. Attempting to

 

 

 

 

program the OVP below this level will result in an execution error response

 

 

(“E04”). The OVP setting stays unchanged.

18

OVP?

Returns the setting “n” where “n” is the exact string in the user’s “OVP n”. When

in Local mode, returns the last setting from the front panel in a 4 digit string.

 

 

19

OVM

Sets OVP level to the maximum level. Refer to Table 7-7.

20

UVL n

Sets Under Voltage Limit. Value of “n” may be equal to PV setting, but returns

“E06” if higher. Refer to Table 7-8 for UVL programming range.

 

 

21

UVL?

Returns the setting “n” where “n” is the exact string in the user’s “UVL n”. When

in Local mode, returns the last setting from the front panel in a 4 digit string.

 

 

 

 

Sets the Auto-restart mode to ON or OFF.

22

AST n

AST 1 (or AST ON): Auto restart On.

 

 

AST 0 (or AST OFF): Auto restart Off.

23

AST?

Returns the string auto-restart mode status.

24

SAV

Saves present settings. The settings are the same as power-down last setting.

These settings are erased when the supply power is switched Off and the new

 

 

“last settings” are saved.

25

RCL

Recalls

last settings. Settings are from the last power-down or from the last

“SAV”

command.

 

 

 

 

 

56

83-507-013 Rev. D

Image 64
Contents Genesystm 750W/1500W Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and Connectors ………...……… Remote Analog PROGRAMMING……………………………………………… Isolated Analog Programming OPTION………………………………… Limitation of Warranty Warranty ServiceDisclaimer Trademark InformationSafety Instructions Environmental Conditions SICHERHEITS-INSTALLATIONS Anweisungen Anderungen and Bauteileersatz Sicherheits-und WarnsymboleUmweltbedingungen Features and options General InformationIntroduction General DescriptionMultiple output power system Control via the serial communication portAnalog voltage programming and monitoring Parallel operationAccessories Specifications ChapterVout Supplemental Characteristics Genesystm 750W & 1500W Power Supplies Outline Drawings Installation GeneralPreparation for USE Initial InspectionsAC Input Power Connection LOCATON, Mounting and CoolingAC Source Requirements Rack Mount Slides optionalAC Input Connector, 1500W models AC Input Connector, 750W modelsAC Input Wire Connection, 1500W models AC Input CordGeneral TURN-ON Checkout ProcedurePrior to Operation Constant Voltage Check Constant Current CheckOVP Check UVL CheckConnecting the Load Wire termination AWGInductive loads Noise and Impedance EffectsMaking the load connections 6V to 60V Models Wire terminal lug 2 places 80V to 600V ModelsLoad wires connection to the output connector Connecting single loads, remote sensing Connecting single loads, local sensing defaultConnecting multiple loads, radial distribution method Multiple load connection with distribution terminals Grounding outputsSense wiring Output Terminal GroundingLocal and Remote Sensing Local sensing10.4 J2 sense connector technical information Remote sensingFront and Rear Panel Controls and Connectors Front Panel Controls and IndicatorsAuxiliary Function Rear Panel Connections and Controls Rear panel connections and controlsRear Panel SW1 Setup Switch Resetting the SW1 switch 1 SW1 position functionRear Panel J1 Programming and Monitorng Connector Making J1 connectionsSignal EnainIfcom LocalConstant Current Mode Constant Voltage ModeLocal Operation Setting the OVP level Resetting the OVP circuitOver Voltage Protection OVP Automatic CrossoverOutput SHUT-OFF SO Control VIA Rear Panel J1 Connector Under Voltage Limit UVLFoldback Protection Output ON/OFF ControlCV/CC Signal ENABLE/DISABLE Control VIA Rear Panel J1 ConnectorPsok Signal Over Temperature Protecton OTP Last Setting MemoryAuto-restart mode Safe-start modeSeries Operation Series connection for increased output voltageSeries connection for positive and negative output voltage Series connection for positive/negative output voltagesParallel Operation Advanced parallel configuration Setting the units as Master or SlaveMaster and Slave units default operation Connection to the loadCurrent display accuracy To release units from Slave modeAST OFF *OUT OFF DAISY-CHAIN Connection Front Panel LockingUnlocked front panel Locked front panelRemote Analog Programming LOCAL/REMOTE Analog IndicationDown Remote voltage programming connectionResisitive Programming of Output Voltage and Current Limit Remote resistive programmingRemote Monitoring of Output Voltage and Current RS232 & RS485 Remote Control Configuration6 RS232/RS485 port in Local mode Rear Panel RS232/RS485 ConnectorFront panel in Remote mode MD Mode Option Factory Installed MD Mode Description MD Mode enable Serial communication modeMD Mode SRQ MD Mode SRQ RetransmissionConnecting Power Supplies to RS232 or RS485 BUS Single power supplyCommunication Interface Protocol Error Messages Command SET DescriptionID Control Commands Initialization Control CommandsOutput Control Commands DVC? FilterFILTER? OUT?Global Output Commands Single Byte Commands Enable MD Mode MD Mode Option RequiredDisable SRQ retransmission MD Mode Option Required Enable SRQ retransmission MD Mode Option RequiredAddressed commands with response Read registers Print Power On TimeTest if MD Mode is Installed Addressed commands without response Acknowledge SRQ1010 None Disable retransmission of SRQs by GEN750W models GEN1500W models Current programming range STATUS, Error and SRQ Registers 10.6 Status Control CommandsConditional Registers Status RegistersService Request Enable and Event Registers BITFault Enable Register Fault Event RegisterStatus Enable Register Status Event RegisterSerial Communication Test SET-UP Power supply set-upCommunication Test Specifications Isolated Analog Programming Option1 0-5V/0-10V Option PN IS510 PPM/CIsolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance Fuse Rating OUP