TDK technical manual GEN750W models GEN1500W models Current programming range

Page 69

GEN750W models

GEN1500W models

Table 7-4: Current programming range

Table 7-5: Current programming range

Model

Minimum

Maximum

(A)

(A)

 

GEN6-100

000.00

100.00

GEN8-90

00.00

90.00

GEN12.5-60

00.000

60.000

GEN20-38

00.000

38.000

GEN30-25

00.000

25.000

GEN40-19

00.000

19.000

GEN60-12.5

00.000

12.500

GEN80-9.5

0.000

9.500

GEN100-7.5

0.000

7.500

GEN150-5

0.000

5.000

GEN300-2.5

0.000

2.500

GEN600-1.3

0.000

1.300

Model

Minimum

Maximum

(A)

(A)

 

GEN6-200

000.00

200.00

GEN8-180

000.00

180.00

GEN12.5-120

000.00

120.00

GEN20-76

00.00

76.00

GEN30-50

00.000

50.000

GEN40-38

00.000

38.000

GEN60-25

00.000

25.000

GEN80-19

00.000

19.000

GEN100-15

00.000

15.000

GEN150-10

00.000

10.000

GEN300-5

0.000

5.000

GEN600-2.6

0.000

2.600

NOTE:

The power supply can accept values higher 5% than the table values, however it is not recommended to program the power supply over the rated values.

Table 7-6: OVP programming range

Model

Minimum

Maximum

Rated Output Voltage (V)

(V)

(V)

 

 

6

0.5

7.50

8

0.5

10.0

12.5

1.0

15.0

20

1.0

24.0

30

2.0

36.0

40

2.0

44.0

60

5.0

66.0

80

5.0

88.0

100

5.0

110.0

150

5.0

165.0

300

5.0

330.0

600

5.0

660.0

Table 7-7: UVL programming range

Model

Minimum

Maximum

Rated Output Voltage (V)

(V)

(V)

 

 

6

0

5.70

8

0

7.60

12.5

0

11.9

20

0

19.0

30

0

28.5

40

0

38.0

60

0

57.0

80

0

76.0

100

0

95.0

150

0

142

300

0

285

600

0

570

61

83-507-013 Rev. D

Image 69
Contents Genesystm 750W/1500W Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and Connectors ………...……… Remote Analog PROGRAMMING……………………………………………… Isolated Analog Programming OPTION………………………………… Warranty Service Limitation of WarrantyDisclaimer Trademark InformationSafety Instructions Environmental Conditions SICHERHEITS-INSTALLATIONS Anweisungen Sicherheits-und Warnsymbole Anderungen and BauteileersatzUmweltbedingungen General Information Features and optionsIntroduction General DescriptionControl via the serial communication port Multiple output power systemAnalog voltage programming and monitoring Parallel operationAccessories Chapter SpecificationsVout Supplemental Characteristics Genesystm 750W & 1500W Power Supplies Outline Drawings General InstallationPreparation for USE Initial InspectionsLOCATON, Mounting and Cooling AC Input Power ConnectionAC Source Requirements Rack Mount Slides optionalAC Input Connector, 750W models AC Input Connector, 1500W modelsAC Input Wire Connection, 1500W models AC Input CordTURN-ON Checkout Procedure GeneralPrior to Operation Constant Current Check Constant Voltage CheckOVP Check UVL CheckConnecting the Load AWG Wire terminationNoise and Impedance Effects Inductive loadsMaking the load connections 6V to 60V Models 80V to 600V Models Wire terminal lug 2 placesLoad wires connection to the output connector Connecting single loads, local sensing default Connecting single loads, remote sensingConnecting multiple loads, radial distribution method Grounding outputs Multiple load connection with distribution terminalsOutput Terminal Grounding Sense wiringLocal and Remote Sensing Local sensingRemote sensing 10.4 J2 sense connector technical informationFront Panel Controls and Indicators Front and Rear Panel Controls and ConnectorsAuxiliary Function Rear panel connections and controls Rear Panel Connections and ControlsRear Panel SW1 Setup Switch 1 SW1 position function Resetting the SW1 switchMaking J1 connections Rear Panel J1 Programming and Monitorng ConnectorEnain SignalIfcom LocalConstant Voltage Mode Constant Current ModeLocal Operation Resetting the OVP circuit Setting the OVP levelOver Voltage Protection OVP Automatic CrossoverUnder Voltage Limit UVL Output SHUT-OFF SO Control VIA Rear Panel J1 ConnectorFoldback Protection Output ON/OFF ControlENABLE/DISABLE Control VIA Rear Panel J1 Connector CV/CC SignalPsok Signal Last Setting Memory Over Temperature Protecton OTPAuto-restart mode Safe-start modeSeries connection for increased output voltage Series OperationSeries connection for positive/negative output voltages Series connection for positive and negative output voltageParallel Operation Setting the units as Master or Slave Advanced parallel configurationMaster and Slave units default operation Connection to the loadTo release units from Slave mode Current display accuracyAST OFF *OUT OFF Front Panel Locking DAISY-CHAIN ConnectionUnlocked front panel Locked front panelLOCAL/REMOTE Analog Indication Remote Analog ProgrammingRemote voltage programming connection DownRemote resistive programming Resisitive Programming of Output Voltage and Current LimitRemote Monitoring of Output Voltage and Current Configuration RS232 & RS485 Remote ControlRear Panel RS232/RS485 Connector 6 RS232/RS485 port in Local modeFront panel in Remote mode MD Mode enable Serial communication mode MD Mode Option Factory Installed MD Mode DescriptionMD Mode SRQ MD Mode SRQ RetransmissionSingle power supply Connecting Power Supplies to RS232 or RS485 BUSCommunication Interface Protocol Command SET Description Error MessagesInitialization Control Commands ID Control CommandsOutput Control Commands Filter DVC?FILTER? OUT?Global Output Commands Enable MD Mode MD Mode Option Required Single Byte CommandsDisable SRQ retransmission MD Mode Option Required Enable SRQ retransmission MD Mode Option RequiredPrint Power On Time Addressed commands with response Read registersTest if MD Mode is Installed Addressed commands without response Acknowledge SRQ1010 None Disable retransmission of SRQs by GEN750W models GEN1500W models Current programming range 10.6 Status Control Commands STATUS, Error and SRQ RegistersStatus Registers Conditional RegistersBIT Service Request Enable and Event RegistersFault Event Register Fault Enable RegisterStatus Event Register Status Enable RegisterPower supply set-up Serial Communication Test SET-UPCommunication Test Isolated Analog Programming Option Specifications1 0-5V/0-10V Option PN IS510 PPM/CIsolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance OUP Fuse Rating