8.3 ISOLATED PROGRAMMING & MONITORING CONNECTOR
Refer to Table
Refer to
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Shield
+VPROG_ISO
+IPROG_ISO GND_ISO
Shield
+IMON_ISO
+VMON_ISO GND_ISO
Fig.8-1: Isolated Programming & Monitoring connector
Table
|
|
| Range | Range | |
Terminal | Signal name | Function | 10V | ||
IS420 option | |||||
|
|
| IS510 option | ||
|
|
|
| ||
1 | SHLD | Shield, connected internally to | Chassis ground | ||
chassis of the power supply. | |||||
|
|
|
| ||
2 | +VPROG_ISO | Output Voltage programming in- | |||
put | |||||
|
|
|
| ||
3 | +IPROG_ISO | Output Current programming in- | |||
put | |||||
|
|
|
| ||
4 | GND | Ground for programming signals. | Ground | Ground | |
|
|
|
|
| |
5 | GND | Ground for programming signals. | Ground | Ground | |
|
|
|
|
| |
6 | +VMON_ISO | Output voltage monitoring output | |||
|
|
|
|
| |
7 | +IMON_ISO | Output current monitoring output | |||
|
|
|
|
| |
8 | SHLD | Shield, connected internally to | Chassis ground | ||
chassis of the supply. | |||||
|
|
|
|
CAUTION
When the Isolated Analog Option is installed, do not apply any signals to the
69